BEGIN:VCALENDAR
VERSION:2.0
PRODID:IEEE vTools.Events//EN
CALSCALE:GREGORIAN
BEGIN:VTIMEZONE
TZID:Europe/Zurich
BEGIN:DAYLIGHT
DTSTART:20190331T030000
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
RRULE:FREQ=YEARLY;BYDAY=-1SU;BYMONTH=3
TZNAME:CEST
END:DAYLIGHT
BEGIN:STANDARD
DTSTART:20181028T020000
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
RRULE:FREQ=YEARLY;BYDAY=-1SU;BYMONTH=10
TZNAME:CET
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTAMP:20181210T134825Z
UID:C60277EC-2FFE-46FF-B05A-0D44D49A2213
DTSTART;TZID=Europe/Zurich:20181207T103000
DTEND;TZID=Europe/Zurich:20181207T120000
DESCRIPTION:More than half of deaths worldwide are due to the top 10 causes
 \, such as ischemic heart disease\, stroke\, chronic obstructive pulmonary
  disease\, etc. Huge money pours into platforms to support disease managem
 ent. Wireless biosensors are one of such platforms\, with their ability to
  measure and communicate parameters that indicate the presence\, or onset\
 , of pathology. The global mobile health market is poised to grow at a CAG
 R of around 32.3% over the next decade to reach approximately $189 billion
  by 2025. This is an explosive trajectory\, yet the development of wireles
 s wearable sensors faces huge challenges. So far there are no satisfactory
  solutions for reliable real-time monitoring of vital signs such as blood 
 pressure and electrocardiogram (ECG)\, not to mention other important para
 meters such as cardiac output\, vessel level flow\, or drug levels to name
  but a few. This talk will cover opportunities and challenges in the devel
 opment of wearable wireless biomedical sensors. The focus is on the energy
  efficient system architecture that utilizes the continuous-in-time and di
 screte-in-amplitude (CTDA) signal flow. The CTDA signal flow enables data 
 compression at the input source\, which greatly reduces the power for wire
 less data transmission. Design examples\, such as [2.89μW wireless ECG So
 C](https://ieeexplore.ieee.org/abstract/document/7526333)\, will be discus
 sed in detail to illustrate the benefits of CTDA system architecture.\n\nC
 o-sponsored by: Inst of Neuroinformatics\, Univ of Zurich/ETH Zurich\n\nSp
 eaker(s): Dr. Yong Lian\, \n\nAgenda: \nWelcome &amp; Networking:  10:30-10:45
 \n\nAnnual meeting of Swiss CASS/EDS: 10:45-11:00\n\nLecture:  11:00-12:00
 \n\nRoom: E81\, Bldg: ETZ\, ETH Zurich\, Gloriastrasse 35\, Zurich\, Switz
 erland\, Switzerland
LOCATION:Room: E81\, Bldg: ETZ\, ETH Zurich\, Gloriastrasse 35\, Zurich\, S
 witzerland\, Switzerland
ORGANIZER:shih@ini.phys.ethz.ch
SEQUENCE:2
SUMMARY:IEEE Swiss CASS Talk by Dr. Yong Lian
URL;VALUE=URI:https://events.vtools.ieee.org/m/183073
X-ALT-DESC:Description: &lt;br /&gt;&lt;p&gt;&lt;span style=&quot;font-weight: 400\;&quot;&gt;More than
  half of deaths worldwide are due to the top 10 causes\, such as ischemic 
 heart disease\, stroke\, chronic obstructive pulmonary disease\, etc. Huge
  money pours into platforms to support disease management. Wireless biosen
 sors are one of such platforms\, with their ability to measure and communi
 cate parameters that indicate the presence\, or onset\, of pathology. The 
 global mobile health market is poised to grow at a CAGR of around 32.3% ov
 er the next decade to reach approximately $189 billion by 2025. This is an
  explosive trajectory\, &lt;/span&gt;&lt;strong&gt;yet the development of wireless wea
 rable sensors faces huge challenges.&lt;/strong&gt;&lt;span style=&quot;font-weight: 400
 \;&quot;&gt; So far there are no satisfactory solutions for reliable real-time mon
 itoring of vital signs such as blood pressure and electrocardiogram (ECG)\
 , not to mention other important parameters such as cardiac output\, vesse
 l level flow\, or drug levels to name but a few. &lt;/span&gt;&lt;strong&gt;This talk 
 will cover opportunities and challenges in the development of wearable wir
 eless biomedical sensors.&lt;/strong&gt;&lt;span style=&quot;font-weight: 400\;&quot;&gt; The fo
 cus is on the energy efficient system architecture that utilizes the conti
 nuous-in-time and discrete-in-amplitude (CTDA) signal flow. The CTDA signa
 l flow enables data compression at the input source\, which greatly reduce
 s the power for wireless data transmission. Design examples\, &lt;/span&gt;&lt;stro
 ng&gt;such as &lt;/strong&gt;&lt;a href=&quot;https://ieeexplore.ieee.org/abstract/document
 /7526333&quot;&gt;&lt;strong&gt;2.89&amp;mu\;W wireless ECG SoC&lt;/strong&gt;&lt;/a&gt;&lt;span style=&quot;fon
 t-weight: 400\;&quot;&gt;\, will be discussed in detail to illustrate the benefits
  of CTDA system architecture.&lt;/span&gt;&lt;/p&gt;&lt;br /&gt;&lt;br /&gt;Agenda: &lt;br /&gt;&lt;p&gt;&lt;span
  style=&quot;font-weight: 400\;&quot;&gt;Welcome &amp;amp\; Networking: &lt;/span&gt; &lt;span style
 =&quot;font-weight: 400\;&quot;&gt;10:30-10:45&lt;/span&gt;&lt;/p&gt;\n&lt;p&gt;&lt;span style=&quot;font-weight:
  400\;&quot;&gt;Annual meeting of Swiss CASS/EDS:&lt;/span&gt; &lt;span style=&quot;font-weight:
  400\;&quot;&gt;10:45-11:00&lt;/span&gt;&lt;/p&gt;\n&lt;p&gt;&lt;span style=&quot;font-weight: 400\;&quot;&gt;Lectur
 e: &lt;/span&gt; &lt;span style=&quot;font-weight: 400\;&quot;&gt;11:00-12:00&lt;/span&gt;&lt;/p&gt;
END:VEVENT
END:VCALENDAR

