BEGIN:VCALENDAR
VERSION:2.0
PRODID:IEEE vTools.Events//EN
CALSCALE:GREGORIAN
BEGIN:VTIMEZONE
TZID:Europe/Bucharest
BEGIN:DAYLIGHT
DTSTART:20190331T040000
TZOFFSETFROM:+0200
TZOFFSETTO:+0300
RRULE:FREQ=YEARLY;BYDAY=-1SU;BYMONTH=3
TZNAME:EEST
END:DAYLIGHT
BEGIN:STANDARD
DTSTART:20191027T030000
TZOFFSETFROM:+0300
TZOFFSETTO:+0200
RRULE:FREQ=YEARLY;BYDAY=-1SU;BYMONTH=10
TZNAME:EET
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTAMP:20190503T184802Z
UID:4D088AD5-D153-4CBA-A1AC-F0B563C3CE8C
DTSTART;TZID=Europe/Bucharest:20190424T100000
DTEND;TZID=Europe/Bucharest:20190424T115900
DESCRIPTION:The WIE IEEE Romania members’ group has actively participated
  at this Technical Activity\, entitled “Non-Oriented Silicon Steels used
  in Electrical Motor Production&quot;\, through its representants Assoc. Prof. 
 Veronica Paltanea and Lecturer Marilena Stanculescu\, which have spoken wi
 th students. Important worldwide guiding rules have been established\, reg
 arding the reduction of electric power consumption and CO2 emissions. The 
 electrical machines should be more efficient\, because their energy consum
 ption accounts for 70 % of industry energy usage. Also\, their carbon foot
 print is high\, and thus it has to be reduced\, by choosing high-performan
 ce electrical machines. In order to comply with IEC 60034-30-1\, the produ
 cers should increase the copper mass in the stator\, use high quality thin
 ner non-oriented electrical steels\, optimize the air-gaps\, and improve a
 lso the cooling systems. The IE3 motors have lower copper losses\, higher 
 inductances and increased starting currents. Comparing an IE3 motor with a
 n IE2 machine it can be concluded that the starting current is 5% higher a
 nd the inrush value is 21% bigger. The motor-protective circuit breakers\,
  contactors\, and overload relays have thus to be designed in a proper man
 ner. Assoc. Prof. Veronica Paltanea have presented the main properties of 
 M400-50A and M400-65A alloys\, used in the IE3 electrical machine magnetic
  cores’ manufacture and M300-35A and NO20 high quality steel grades for 
 IE4 motors. The samples were characterized with a laboratory single sheet 
 tester\, which consists of a double C laminated yoke and two concentric so
 lenoids of 150 mm magnetic path length. One of them has 173 turns and it i
 s used to generate the magnetic field\; the other one is placed near the t
 ested sample\, has 101 turns and acts as a pickup coil for the secondary v
 oltage. Energy losses and magnetic permeability were determined\, by contr
 olling the sinusoidal waveform of the secondary voltage according to the I
 EC 60404-3 standard in the frequency range 3 Hz – 400 Hz at peak magneti
 c polarization Jp = 1 T\, using a 12 bit 500 MHz HDO4054 LeCroy oscillosco
 pe\, for the acquisition of the signals. Lecturer Marilena Stanculescu has
  explained the loss separation concept and presented the experimental resu
 lts with supplementary explanation regarding the chemical composition of t
 he electrical steel and metallurgical processes. The WIE group through its
  representanst Assoc. Prof. Veronica Paltanea and Lecturer Marilena Stancu
 lescu have decided to continue with another technical and administrative a
 ctivities\, because the students are very interested in new trends in elec
 trical machines.\n\nSpeaker(s): Assoc. Prof. Veronica Paltanea\, Lecturer 
 Marilena Stanculescu\n\nRoom: EB 210\, Bldg: Electrical Engineering Facult
 y\, University Politehnica of Bucharest\, 313 Splaiul Independentei\, Dist
 rict 6\, Bucharest\, Romania\, Bucharest\, Municipiul Bucuresti\, Romania\
 , RO-060042
LOCATION:Room: EB 210\, Bldg: Electrical Engineering Faculty\, University P
 olitehnica of Bucharest\, 313 Splaiul Independentei\, District 6\, Buchare
 st\, Romania\, Bucharest\, Municipiul Bucuresti\, Romania\, RO-060042
ORGANIZER:m1vera2@yahoo.com
SEQUENCE:2
SUMMARY:Non-Oriented Silicon Steels used in Electrical Motor Production
URL;VALUE=URI:https://events.vtools.ieee.org/m/198606
X-ALT-DESC:Description: &lt;br /&gt;&lt;p&gt;The WIE IEEE Romania members&amp;rsquo\; group
  has actively participated at this Technical Activity\, entitled &amp;ldquo\;N
 on-Oriented Silicon Steels used in Electrical Motor Production&quot;\, through 
 its representants Assoc. Prof. Veronica Paltanea and Lecturer Marilena Sta
 nculescu\, which have spoken with students. Important worldwide guiding ru
 les have been established\, regarding the reduction of electric power cons
 umption and CO&lt;sub&gt;2&lt;/sub&gt; emissions. The electrical machines should be mo
 re efficient\, because their energy consumption accounts for 70 % of indus
 try energy usage. Also\, their carbon footprint is high\, and thus it has 
 to be reduced\, by choosing high-performance electrical machines. In order
  to comply with IEC 60034-30-1\, the producers should increase the copper 
 mass in the stator\, use high quality thinner non-oriented electrical stee
 ls\, optimize the air-gaps\, and improve also the cooling systems. The IE3
  motors have lower copper losses\, higher inductances and increased starti
 ng currents. Comparing an IE3 motor with an IE2 machine it can be conclude
 d that the starting current is 5% higher and the inrush value is 21% bigge
 r. The motor-protective circuit breakers\, contactors\, and overload relay
 s have thus to be designed in a proper manner. Assoc. Prof. Veronica Palta
 nea have presented the main properties of M400-50A and M400-65A alloys\, u
 sed in the IE3 electrical machine magnetic cores&amp;rsquo\; manufacture and M
 300-35A and NO20 high quality steel grades for IE4 motors. The samples wer
 e characterized with a laboratory single sheet tester\, which consists of 
 a double C laminated yoke and two concentric solenoids of 150 mm magnetic 
 path length. One of them has 173 turns and it is used to generate the magn
 etic field\; the other one is placed near the tested sample\, has 101 turn
 s and acts as a pickup coil for the secondary voltage. Energy losses and m
 agnetic permeability were determined\, by controlling the sinusoidal wavef
 orm of the secondary voltage according to the IEC 60404-3 standard in the 
 frequency range 3 Hz &amp;ndash\; 400 Hz at peak magnetic polarization Jp = 1 
 T\, using a 12 bit 500 MHz HDO4054 LeCroy oscilloscope\, for the acquisiti
 on of the signals. Lecturer Marilena Stanculescu has explained the loss se
 paration concept and presented the experimental results with supplementary
  explanation regarding the chemical composition of the electrical steel an
 d metallurgical processes.&amp;nbsp\;The WIE group through its representanst A
 ssoc. Prof. Veronica Paltanea and Lecturer Marilena Stanculescu have decid
 ed to continue with another technical and administrative activities\, beca
 use the students are very interested in new trends in electrical machines.
 &lt;/p&gt;
END:VEVENT
END:VCALENDAR

