BEGIN:VCALENDAR
VERSION:2.0
PRODID:IEEE vTools.Events//EN
CALSCALE:GREGORIAN
BEGIN:VTIMEZONE
TZID:Poland
BEGIN:DAYLIGHT
DTSTART:20210328T030000
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
RRULE:FREQ=YEARLY;BYDAY=-1SU;BYMONTH=3
TZNAME:CEST
END:DAYLIGHT
BEGIN:STANDARD
DTSTART:20201025T020000
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
RRULE:FREQ=YEARLY;BYDAY=-1SU;BYMONTH=10
TZNAME:CET
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTAMP:20210913T190110Z
UID:39F38106-A769-47F9-AFA4-5F5362D6533F
DTSTART;TZID=Poland:20210302T090000
DTEND;TZID=Poland:20210302T150000
DESCRIPTION:EMC - metrological issues\n\nCo-sponsored by: Łukasiewicz - IL
 iM\, Politechnika Warszawska\, Raditeq\n\nAgenda: \nEtap III\n\n2 March 20
 21\n\nThe main topic\nEMC - metrological issues\n\nA. 11.00-12.15\nUncerta
 inty budget based on the example of magnetic field resistance tests accord
 ing to EN 61000-4-8\n(in Polish)\n\nTheoretical basis\, practical examples
  of validating the test method and determining the uncertainty of the test
  signal measurements\n\nPresenter\n\nJan Sroka\, Politechnika Warszawska\,
  Poland\n\nB. 12.30-13.00\nAutomatic verification of surge surge pulses an
 d fast electrical transients in the LabView environment\n(in Polish)\n\nBa
 sic EMC standards\, pulse definition\, LabView environment - individual pr
 ogramming to automate the control of a digital oscilloscope.\n\nPresenter\
 n\nAdam Maćkowiak\, Ł-ILiM\, Krzysztof Sieczkarek\, Ł-ILiM\n\nC. 13.15.
 00-14.30\n\nIsotropic behaviour. The forgotten specification\n(in English)
 \n\nEMC research laboratories use electric field probes to determine the i
 ntensity of the electric field generated in anechoic chambers. The electri
 c field probe is the (only) absolute reference for verifying the value of 
 the generated electric field strength. Therefore\, the accuracy of the E-f
 ield probes is of great importance. The theory and practice of the topic o
 f isotropy and the implications of the isotropic behavior of electric fiel
 d probes will be demonstrated.\n\nPresenter\n\nEdwin vom Hofe\, Raditeq (D
 are!!)\, The Netherlands\n\nVirtual: https://events.vtools.ieee.org/m/2609
 93
LOCATION:Virtual: https://events.vtools.ieee.org/m/260993
ORGANIZER:Krzysztof.Sieczkarek@ilim.lukasiewicz.gov.pl
SEQUENCE:7
SUMMARY:IEEE EMC-S PL reported activity no. 04/2021: &quot;MARATON EMC 2021 Wint
 er Edition ETAP 3&quot;
URL;VALUE=URI:https://events.vtools.ieee.org/m/260993
X-ALT-DESC:Description: &lt;br /&gt;&lt;p&gt;&lt;strong&gt;EMC - metrological issues&lt;/strong&gt;
 &lt;/p&gt;&lt;br /&gt;&lt;br /&gt;Agenda: &lt;br /&gt;&lt;p&gt;&amp;nbsp\;&lt;/p&gt;\n&lt;table&gt;\n&lt;tbody&gt;\n&lt;tr&gt;\n&lt;td 
 width=&quot;170&quot;&gt;\n&lt;p&gt;&lt;strong&gt;Etap III&lt;/strong&gt;&lt;/p&gt;\n&lt;/td&gt;\n&lt;td colspan=&quot;2&quot; wid
 th=&quot;396&quot;&gt;\n&lt;p&gt;&lt;strong&gt;2 March 2021&lt;/strong&gt;&lt;/p&gt;\n&lt;/td&gt;\n&lt;/tr&gt;\n&lt;tr&gt;\n&lt;td w
 idth=&quot;170&quot;&gt;\n&lt;p&gt;The main topic&lt;/p&gt;\n&lt;/td&gt;\n&lt;td colspan=&quot;2&quot; width=&quot;396&quot;&gt;&lt;st
 rong&gt;EMC - metrological issues&lt;/strong&gt;\n&lt;p&gt;&lt;strong&gt;&amp;nbsp\;&lt;/strong&gt;&lt;/p&gt;\n
 &lt;/td&gt;\n&lt;/tr&gt;\n&lt;tr&gt;\n&lt;td width=&quot;170&quot;&gt;\n&lt;p&gt;&amp;nbsp\;&lt;/p&gt;\n&lt;/td&gt;\n&lt;td width=&quot;16
 4&quot;&gt;\n&lt;p&gt;&amp;nbsp\;&lt;/p&gt;\n&lt;/td&gt;\n&lt;td width=&quot;231&quot;&gt;\n&lt;p&gt;&amp;nbsp\;&lt;/p&gt;\n&lt;/td&gt;\n&lt;/tr&gt;
 \n&lt;tr&gt;\n&lt;td width=&quot;170&quot;&gt;\n&lt;p&gt;A. 11.00-12.15&lt;/p&gt;\n&lt;/td&gt;\n&lt;td colspan=&quot;2&quot; wi
 dth=&quot;396&quot;&gt;&lt;strong&gt;Uncertainty budget based on the example of magnetic fiel
 d resistance tests according to EN 61000-4-8&lt;br /&gt;&lt;/strong&gt;(in Polish)&lt;str
 ong&gt;&amp;nbsp\;&lt;/strong&gt;\n&lt;p&gt;&lt;strong&gt;&amp;nbsp\;&lt;/strong&gt;&lt;/p&gt;\n&lt;/td&gt;\n&lt;/tr&gt;\n&lt;tr&gt;\
 n&lt;td width=&quot;170&quot;&gt;\n&lt;p&gt;&amp;nbsp\;&lt;/p&gt;\n&lt;/td&gt;\n&lt;td colspan=&quot;2&quot; width=&quot;396&quot;&gt;Theo
 retical basis\, practical examples of validating the test method and deter
 mining the uncertainty of the test signal measurements\n&lt;p&gt;&amp;nbsp\;&lt;/p&gt;\n&lt;/
 td&gt;\n&lt;/tr&gt;\n&lt;tr&gt;\n&lt;td width=&quot;170&quot;&gt;\n&lt;p&gt;Presenter&lt;/p&gt;\n&lt;/td&gt;\n&lt;td colspan=&quot;
 2&quot; width=&quot;396&quot;&gt;\n&lt;p&gt;&lt;em&gt;Jan Sroka\, Politechnika Warszawska&lt;/em&gt;&lt;em&gt;\, Pol
 and&lt;/em&gt;&lt;/p&gt;\n&lt;/td&gt;\n&lt;/tr&gt;\n&lt;tr&gt;\n&lt;td colspan=&quot;3&quot; width=&quot;566&quot;&gt;\n&lt;p&gt;&amp;nbsp\;
 &lt;/p&gt;\n&lt;/td&gt;\n&lt;/tr&gt;\n&lt;tr&gt;\n&lt;td width=&quot;170&quot;&gt;\n&lt;p&gt;B. 12.30-13.00&lt;/p&gt;\n&lt;/td&gt;\n
 &lt;td colspan=&quot;2&quot; width=&quot;396&quot;&gt;&lt;strong&gt;Automatic verification of surge surge 
 pulses and fast electrical transients in the LabView environment&lt;br /&gt;&lt;/st
 rong&gt;(in Polish)\n&lt;h2&gt;&amp;nbsp\;&lt;/h2&gt;\n&lt;/td&gt;\n&lt;/tr&gt;\n&lt;tr&gt;\n&lt;td width=&quot;170&quot;&gt;\n
 &lt;p&gt;&amp;nbsp\;&lt;/p&gt;\n&lt;/td&gt;\n&lt;td colspan=&quot;2&quot; width=&quot;396&quot;&gt;Basic EMC standards\, p
 ulse definition\, LabView environment - individual programming to automate
  the control of a digital oscilloscope.\n&lt;p&gt;&amp;nbsp\;&lt;/p&gt;\n&lt;/td&gt;\n&lt;/tr&gt;\n&lt;tr
 &gt;\n&lt;td width=&quot;170&quot;&gt;\n&lt;p&gt;Presenter&lt;/p&gt;\n&lt;/td&gt;\n&lt;td colspan=&quot;2&quot; width=&quot;396&quot;&gt;
 \n&lt;h2&gt;&lt;span style=&quot;font-size: 12pt\;&quot;&gt;&lt;em&gt;Adam Maćkowiak\, Ł-ILiM\, Krzy
 sztof Sieczkarek\, Ł-ILiM&lt;/em&gt;&lt;/span&gt;&lt;/h2&gt;\n&lt;/td&gt;\n&lt;/tr&gt;\n&lt;tr&gt;\n&lt;td colsp
 an=&quot;3&quot; width=&quot;566&quot;&gt;\n&lt;p&gt;&amp;nbsp\;&lt;/p&gt;\n&lt;/td&gt;\n&lt;/tr&gt;\n&lt;tr&gt;\n&lt;td width=&quot;170&quot;&gt;\
 n&lt;p&gt;C. 13.15.00-14.30&lt;/p&gt;\n&lt;/td&gt;\n&lt;td colspan=&quot;2&quot; width=&quot;396&quot;&gt;\n&lt;h2&gt;&lt;span 
 style=&quot;font-size: 10pt\;&quot;&gt;Isotropic behaviour. The forgotten specification
  &lt;/span&gt;&lt;br /&gt;&lt;span style=&quot;font-size: 10pt\;&quot;&gt; (in English)&lt;/span&gt;&lt;/h2&gt;\n&lt;
 /td&gt;\n&lt;/tr&gt;\n&lt;tr&gt;\n&lt;td width=&quot;170&quot;&gt;\n&lt;p&gt;&amp;nbsp\;&lt;/p&gt;\n&lt;/td&gt;\n&lt;td colspan=&quot;2
 &quot; width=&quot;396&quot;&gt;EMC research laboratories use electric field probes to deter
 mine the intensity of the electric field generated in anechoic chambers. T
 he electric field probe is the (only) absolute reference for verifying the
  value of the generated electric field strength. Therefore\, the accuracy 
 of the E-field probes is of great importance. The theory and practice of t
 he topic of isotropy and the implications of the isotropic behavior of ele
 ctric field probes will be demonstrated.\n&lt;p&gt;&amp;nbsp\;&lt;/p&gt;\n&lt;/td&gt;\n&lt;/tr&gt;\n&lt;t
 r&gt;\n&lt;td width=&quot;170&quot;&gt;\n&lt;p&gt;Presenter&lt;/p&gt;\n&lt;/td&gt;\n&lt;td colspan=&quot;2&quot; width=&quot;396&quot;
 &gt;\n&lt;h2&gt;&lt;span style=&quot;font-size: 10pt\;&quot;&gt;&lt;em&gt;Edwin vom Hofe\, Raditeq (Dare!
 !)\, &lt;/em&gt;&lt;em&gt;The Netherlands&lt;/em&gt;&lt;/span&gt;&lt;/h2&gt;\n&lt;/td&gt;\n&lt;/tr&gt;\n&lt;/tbody&gt;\n&lt;/
 table&gt;\n&lt;p&gt;&amp;nbsp\;&lt;/p&gt;
END:VEVENT
END:VCALENDAR

