DESCRIPTION:This course provides an introduction and overview of alarm mana
 gement. We will review a history of alarm management published standards A
 NSI/ISA18.2\, Management of Alarm Systems for the Process Industries\, and
  the IEC version\, IEC62682 of the same name.\n\nThe course will provide a
 n introduction to what are standards and how they are used by regulatory b
 odies. In addition\, the course will cover the importance of alarm managem
 ent and review several significant industry incidents in which casual fact
 ors were due to poor alarm management.\n\nThe alarm management lifecycle f
 rom ISA18.2 and IEC62682 will be introduced and the parts of the lifecycle
  will be covered. These activities include alarm philosophy development\, 
 alarm rationalization\, basic alarm design\, advanced alarm techniques\, H
 MI design for alarms\, monitoring\, assessment\, management of change\, an
 d audit. We will discuss the entry points to the lifecycle for starting al
 arm management improvement projects.\n\nFinally\, we will discuss key alar
 m management references for you to utilize in your alarm management improv
 ement projects.\n\nParticipants will learn about the standards for alarm m
 anagement and the lifecycle and how they address the common problems of al
 arm systems.\n\nKey benefits of this course include:\n\n- Learning about t
 he alarm management standards and how standard impact you\n- Learning the 
 requirements of the standards on the Management of Alarm Systems\n- Learni
 ng the alarm management lifecycle\n- Learning about the common alarm manag
 ement problems\n- Learning the best practices to improve the alarm system 
 performance\n- Learning the metrics to measure success in alarm management
 \n\n[Eaton Experience Center Virtual Tour](https://www.eaton.com/us/en-us/
 markets/eaton-experience-centers/virtual-tours/houston.html)\n\nCo-sponsor
 ed by: Houston Section\n\nSpeaker(s): Donald Dunn\, ISA Fellow and IEEE Fe
 llow\, Waldemar S. Nelson &amp; Co.\, \n\nAgenda: \nVisit [IEEE 2022 GreenTech
  Program\, CED On-Demand\, and Workshops &amp; Tutorials](https://ieeegreentec
 h.org/program/) page for additional schedules and options.\n\nBldg: Eaton 
 Experience Center\, 3413 North Sam Houston Pkwy W\, Houston\, Texas\, Unit
 ed States\, 77086
LOCATION:Bldg: Eaton Experience Center\, 3413 North Sam Houston Pkwy W\, Ho
 uston\, Texas\, United States\, 77086
ORGANIZER:christopher.b.sanderson@ieee.org
SEQUENCE:5
SUMMARY:GT CED: Introduction to Alarm Management – An Overview of ISA 18.
 2 &amp; IEC 62682
URL;VALUE=URI:https://events.vtools.ieee.org/m/306332
X-ALT-DESC:Description: &lt;br /&gt;&lt;p&gt;This course provides an introduction and o
 verview of alarm management. We will review a history of alarm management 
 published standards ANSI/ISA18.2\, Management of Alarm Systems for the Pro
 cess Industries\, and the IEC version\, IEC62682 of the same name.&lt;/p&gt;\n&lt;p
 &gt;The course will provide an introduction to what are standards and how the
 y are used by regulatory bodies. In addition\, the course will cover the i
 mportance of alarm management and review several significant industry inci
 dents in which casual factors were due to poor alarm management.&lt;/p&gt;\n&lt;p&gt;T
 he alarm management lifecycle from ISA18.2 and IEC62682 will be introduced
  and the parts of the lifecycle will be covered. These activities include 
 alarm philosophy development\, alarm rationalization\, basic alarm design\
 , advanced alarm techniques\, HMI design for alarms\, monitoring\, assessm
 ent\, management of change\, and audit. We will discuss the entry points t
 o the lifecycle for starting alarm management improvement projects.&lt;/p&gt;\n&lt;
 p&gt;Finally\, we will discuss key alarm management references for you to uti
 lize in your alarm management improvement projects.&lt;/p&gt;\n&lt;p&gt;Participants w
 ill learn about the standards for alarm management and the lifecycle and h
 ow they address the common problems of alarm systems.&lt;/p&gt;\n&lt;p&gt;&lt;em&gt;&lt;strong&gt;
 Key benefits of this course include:&lt;/strong&gt;&lt;/em&gt;&lt;/p&gt;\n&lt;ul&gt;\n&lt;li&gt;Learning
  about the alarm management standards and how standard impact you&lt;/li&gt;\n&lt;l
 i&gt;Learning the requirements of the standards on the Management of Alarm Sy
 stems&lt;/li&gt;\n&lt;li&gt;Learning the alarm management lifecycle&lt;/li&gt;\n&lt;li&gt;Learning
  about the common alarm management problems&lt;/li&gt;\n&lt;li&gt;Learning the best pr
 actices to improve the alarm system performance&lt;/li&gt;\n&lt;li&gt;Learning the met
 rics to measure success in alarm management&lt;/li&gt;\n&lt;/ul&gt;\n&lt;p&gt;&lt;a href=&quot;https
 ://www.eaton.com/us/en-us/markets/eaton-experience-centers/virtual-tours/h
 ouston.html&quot; target=&quot;_blank&quot; rel=&quot;noopener&quot;&gt;Eaton Experience Center Virtua
 l Tour&lt;/a&gt;&lt;/p&gt;&lt;br /&gt;&lt;br /&gt;Agenda: &lt;br /&gt;&lt;p&gt;Visit &lt;a href=&quot;https://ieeegree
 ntech.org/program/&quot; target=&quot;_blank&quot; rel=&quot;noopener&quot;&gt;IEEE 2022 GreenTech Pro
 gram\, CED On-Demand\, and Workshops &amp;amp\; Tutorials&lt;/a&gt; page for additio
 nal schedules and options.&amp;nbsp\;&lt;/p&gt;
END:VEVENT
END:VCALENDAR