DESCRIPTION:The PES and IAS Chapters will sponsor a technical seminar on th
 e topic of Generator and Transformer Protection. The session will be held 
 on Friday\, January 23\, 2015 at PSE&amp;G’s Hadley Road Facility\, 4000 Had
 ley Road\, South Plainfield\, NJ 07080-1192.\n\nTopic:\n\nThe seminar will
  cover Generator Protection including:\n\n-\nReview of Grounding Technique
 s and Types of Generator Connections\n\n-\nGenerator Protection as per IEE
 E C37.102\, C37.101\, C37.106 and NERC PRC standards\n\n-\nNegative Sequen
 ce Protection Down to Continuous Rating\n\n-\n100% Stator Ground Fault –
  Third Harmonic vs. Injection Method\n\n-\nField Ground Fault detection wi
 th Injection Method\n\n-\nOverexcitation (V/Hz) protection\n\n-\nLow Direc
 tional Power Sensitivity Requirements for Sequential Tripping\n\n-\nDistan
 ce Element Enhancements - Load Encroachment Blinding\, Power Swing Blockin
 g\n\n-\nOut-of-Step Protection\n\n-\nLoss of Field - Element Design to Mat
 ch Machine Capability Curves\, MEL and Steady State Stability\n\n-\nAbnorm
 al Frequency Protection\n\nThe seminar will cover Transformer Protection i
 ncluding:\n\n-\nModes of Transformer Failures\n\n-\nTypes of Protection: P
 hase &amp; Ground Differential\, Overcurrent\, Overexcitation\,\n\n-\nUnique F
 actors for Differential Protection\n\n-\nCurrent Magnitude/Phase Differenc
 es\n\n-\nEffect on Differential Protection: In-Rush Phenomena\, CT Saturat
 ion\, Overexcitation\n\n-\nUse of a Ground Differential Element for Sensit
 ive Ground Fault Protection\n\n-\nAdvanced Transformer Inrush and Overexci
 tation Detection providing Improved Security\n\n-\nCurrent Summing for Tra
 nsformer Overcurrent Protection in Breaker and a Half/Ring bus\n\n-\nThrou
 gh-Fault Accumulation &amp; Alarm\n\nSpeaker(s): Murty V.V.S. Yalla\, \, Murty
  V.V.S. Yalla\, \, Murty V.V.S. Yalla\, \n\nAgenda: \nThe seminar fee incl
 udes lunch\, refreshments and handouts. Non-members joining IEEE within 30
  days of the seminar will be rebated 50% of the IEEE registration charge. 
 Four hours of instruction will be provided. If desired\, IEEE Continuing E
 ducation Units (0.4 CEUs) will be offered for this course - a small fee of
  $45 will be required for processing. Please pay attention to the “Regis
 tration Fee” and choose the appropriate choice either with or without CE
 Us.\n\nRoom: Auditorium\, Bldg: PSE&amp;G - Hadley Road Facility\, 4000 Hadley
  Road\, South Plainfield\, New Jersey\, United States\, 07080 
LOCATION:Room: Auditorium\, Bldg: PSE&amp;G - Hadley Road Facility\, 4000 Hadle
 y Road\, South Plainfield\, New Jersey\, United States\, 07080 
ORGANIZER:RWQuade@ieee.org
SEQUENCE:9
SUMMARY:Generator and Transformer Protection
URL;VALUE=URI:https://events.vtools.ieee.org/m/31363
X-ALT-DESC:Description: &lt;br /&gt;&lt;p&gt;The PES and IAS Chapters will sponsor a te
 chnical seminar on the topic of Generator and Transformer Protection.&amp;nbsp
 \; The session will be held on Friday\, January 23\, 2015 at PSE&amp;amp\;G&amp;rs
 quo\;s Hadley Road Facility\, 4000 Hadley Road\, South Plainfield\, NJ&amp;nbs
 p\; 07080-1192.&lt;/p&gt;\n&lt;p&gt;&amp;nbsp\;&lt;/p&gt;\n&lt;p&gt;Topic:&lt;/p&gt;\n&lt;p&gt;The seminar will co
 ver Generator Protection including:&amp;nbsp\;&lt;/p&gt;\n&lt;ul&gt;\n&lt;li&gt;\n&lt;p&gt;Review of G
 rounding Techniques and Types of Generator Connections&lt;/p&gt;\n&lt;/li&gt;\n&lt;li&gt;\n&lt;
 p&gt;Generator Protection as per IEEE C37.102\, C37.101\, C37.106 and NERC PR
 C standards&lt;/p&gt;\n&lt;/li&gt;\n&lt;li&gt;\n&lt;p&gt;Negative Sequence Protection Down to Cont
 inuous Rating&lt;/p&gt;\n&lt;/li&gt;\n&lt;li&gt;\n&lt;p&gt;100% Stator Ground Fault &amp;ndash\; Third
  Harmonic vs. Injection Method&lt;/p&gt;\n&lt;/li&gt;\n&lt;li&gt;\n&lt;p&gt;Field Ground Fault det
 ection with Injection Method&lt;/p&gt;\n&lt;/li&gt;\n&lt;li&gt;\n&lt;p&gt;Overexcitation (V/Hz) pr
 otection&lt;/p&gt;\n&lt;/li&gt;\n&lt;li&gt;\n&lt;p&gt;Low Directional Power Sensitivity Requiremen
 ts for Sequential Tripping&lt;/p&gt;\n&lt;/li&gt;\n&lt;li&gt;\n&lt;p&gt;Distance Element Enhanceme
 nts - Load Encroachment Blinding\, Power Swing Blocking&lt;/p&gt;\n&lt;/li&gt;\n&lt;li&gt;\n
 &lt;p&gt;Out-of-Step Protection&lt;/p&gt;\n&lt;/li&gt;\n&lt;li&gt;\n&lt;p&gt;Loss of Field - Element Des
 ign to Match Machine Capability Curves\, MEL and Steady State Stability&lt;/p
 &gt;\n&lt;/li&gt;\n&lt;li&gt;\n&lt;p&gt;Abnormal Frequency Protection&lt;/p&gt;\n&lt;/li&gt;\n&lt;/ul&gt;\n&lt;p&gt;&amp;nb
 sp\;&amp;nbsp\;&lt;/p&gt;\n&lt;p&gt;The seminar will cover Transformer Protection includin
 g:&lt;/p&gt;\n&lt;ul&gt;\n&lt;li&gt;\n&lt;p&gt;Modes of Transformer Failures&lt;/p&gt;\n&lt;/li&gt;\n&lt;li&gt;\n&lt;p&gt;
 Types of Protection: Phase &amp;amp\; Ground Differential\, Overcurrent\, Over
 excitation\,&lt;/p&gt;\n&lt;/li&gt;\n&lt;li&gt;\n&lt;p&gt;Unique Factors for Differential Protecti
 on&lt;/p&gt;\n&lt;ul&gt;\n&lt;li&gt;\n&lt;p&gt;Current Magnitude/Phase Differences&lt;/p&gt;\n&lt;/li&gt;\n&lt;li
 &gt;\n&lt;p&gt;Effect on Differential Protection: In-Rush Phenomena\, CT Saturation
 \, Overexcitation&lt;/p&gt;\n&lt;/li&gt;\n&lt;li&gt;\n&lt;p&gt;Use of a Ground Differential Elemen
 t for Sensitive Ground Fault Protection&lt;/p&gt;\n&lt;/li&gt;\n&lt;/ul&gt;\n&lt;/li&gt;\n&lt;li&gt;\n&lt;p
 &gt;Advanced Transformer Inrush and Overexcitation Detection providing Improv
 ed Security&lt;/p&gt;\n&lt;/li&gt;\n&lt;li&gt;\n&lt;p&gt;Current Summing for Transformer Overcurre
 nt Protection in Breaker and a Half/Ring bus&lt;/p&gt;\n&lt;/li&gt;\n&lt;li&gt;\n&lt;p&gt;Through-
 Fault Accumulation &amp;amp\; Alarm&lt;/p&gt;\n&lt;/li&gt;\n&lt;/ul&gt;&lt;br /&gt;&lt;br /&gt;Agenda: &lt;br /
 &gt;&lt;p&gt;The seminar fee includes lunch\, refreshments and handouts. Non-member
 s joining IEEE within 30 days of the seminar will be rebated 50% of the IE
 EE registration charge. Four hours of instruction will be provided. If des
 ired\, IEEE Continuing Education Units (0.4 CEUs) will be offered for this
  course - a small fee of $45 will be required for processing. Please pay a
 ttention to the &amp;ldquo\;Registration Fee&amp;rdquo\; and choose the appropriat