BEGIN:VCALENDAR
VERSION:2.0
PRODID:IEEE vTools.Events//EN
CALSCALE:GREGORIAN
BEGIN:VTIMEZONE
TZID:America/Chicago
BEGIN:DAYLIGHT
DTSTART:20220313T030000
TZOFFSETFROM:-0600
TZOFFSETTO:-0500
RRULE:FREQ=YEARLY;BYDAY=2SU;BYMONTH=3
TZNAME:CDT
END:DAYLIGHT
BEGIN:STANDARD
DTSTART:20221106T010000
TZOFFSETFROM:-0500
TZOFFSETTO:-0600
RRULE:FREQ=YEARLY;BYDAY=1SU;BYMONTH=11
TZNAME:CST
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTAMP:20220606T161218Z
UID:631F1AD5-732D-4F4B-948A-CD92FB2CC8CC
DTSTART;TZID=America/Chicago:20220601T120000
DTEND;TZID=America/Chicago:20220601T130000
DESCRIPTION:ABOUT THE SPEAKER\n\nTodd D. Vought is an LPI. Certified Master
  Designer / Installer of Lightning Protection Systems with LYNCOLE VFC. Mr
 . Vought has been certified since 1984. VFC has been protecting North Amer
 ican facilities and infrastructure since 1989. Since then\, it has grown i
 nto the nation&#39;s largest Lightning Protection Company. Our Lightning Prote
 ction and Specialty Grounding Systems are deployed throughout the United S
 tates and internationally. LYNCOLE is a division of VFC\, The inventors of
  the XIT Electrolytic Grounding System\, provides Advanced Grounding Solut
 ions and Engineering Services.\n\nTOPIC\n\nThe risk of lightning strikes o
 n people\, structures\, and businesses is increasing. Two major factors ar
 e driving this trend: bigger cities and global climate change. In the US a
 lone\, total lightning-related damage and disruption currently cost $8 to 
 $10 billion annually\, rising at nearly 20% per year. Yet for risk mitigat
 ion and damage avoidance\, cost-effective lightning protection systems are
  readily available. Truly lightning resilient facilities can protect peopl
 e and save industry and the public sector billions of dollars each year. I
 n this presentation\, Mr. Vought reviews effective design and implementati
 on principles of lightning resilient buildings\, including:\n\n- Need for 
 Lightning Resilience\n- Risk Assessment •NFPA Annex L\n- Lightning Pheno
 menon Basics\n- Facility Lightning Protection\n- Grounding\n- Bonding – 
 Potential Equalization • NEC Bonding\n- Surge Suppression – SPD&#39;s\n- S
 tructural Lightning Protection Basics • Conventional Systems\n- Structur
 al Lightning Protection Basics • Zone of Protection Analysis\n- Every Fa
 cility is Unique\n- Keys To Successful Facility Protection • Comprehensi
 ve Design\n\nAgenda: \n12:00PM Presentation\n\n12:50PM Questions\n\n1:00PM
  Adjourn\n\nVirtual: https://events.vtools.ieee.org/m/315026
LOCATION:Virtual: https://events.vtools.ieee.org/m/315026
ORGANIZER:mmorris@ieee.org
SEQUENCE:4
SUMMARY:Creating Lightning Resilient Facilities
URL;VALUE=URI:https://events.vtools.ieee.org/m/315026
X-ALT-DESC:Description: &lt;br /&gt;&lt;p&gt;&lt;strong&gt;ABOUT THE SPEAKER&lt;/strong&gt;&lt;/p&gt;\n&lt;p
 &gt;Todd D. Vought is an LPI. Certified Master Designer / Installer of Lightn
 ing Protection Systems with LYNCOLE VFC. Mr. Vought has been certified sin
 ce 1984.&amp;nbsp\; VFC has been protecting North American facilities and infr
 astructure since 1989. Since then\, it&amp;nbsp\;has grown into the nation&#39;s l
 argest Lightning Protection Company. Our Lightning Protection and Specialt
 y Grounding Systems are deployed throughout the United States and internat
 ionally.&amp;nbsp\; LYNCOLE is a division of VFC\, The inventors of the XIT El
 ectrolytic Grounding System\, provides Advanced Grounding Solutions and En
 gineering Services.&lt;/p&gt;\n&lt;p&gt;&lt;strong&gt;TOPIC&lt;/strong&gt;&lt;/p&gt;\n&lt;p&gt;The risk of lig
 htning strikes on people\, structures\, and businesses is increasing. Two 
 major factors are driving this trend: bigger cities and global climate cha
 nge. In the US alone\, total lightning-related damage and disruption curre
 ntly cost $8 to $10 billion annually\, rising at nearly 20% per year. Yet 
 for risk mitigation and damage avoidance\, cost-effective lightning protec
 tion systems are readily available. Truly lightning resilient facilities c
 an protect people and save industry and the public sector billions of doll
 ars each year.&amp;nbsp\; In this presentation\, Mr. Vought reviews effective 
 design and implementation principles of lightning resilient buildings\, in
 cluding:&lt;/p&gt;\n&lt;ul&gt;\n&lt;li&gt;Need for Lightning Resilience&lt;/li&gt;\n&lt;li&gt;Risk Asses
 sment &amp;bull\;NFPA Annex L&lt;/li&gt;\n&lt;li&gt;Lightning Phenomenon Basics&lt;/li&gt;\n&lt;li&gt;
 Facility Lightning Protection&lt;/li&gt;\n&lt;li&gt;Grounding&lt;/li&gt;\n&lt;li&gt;Bonding &amp;ndash
 \; Potential Equalization &amp;bull\; NEC Bonding&lt;/li&gt;\n&lt;li&gt;Surge Suppression 
 &amp;ndash\; SPD&#39;s&lt;/li&gt;\n&lt;li&gt;Structural Lightning Protection Basics &amp;bull\; Co
 nventional Systems&lt;/li&gt;\n&lt;li&gt;Structural Lightning Protection Basics &amp;bull\
 ; Zone of Protection Analysis&lt;/li&gt;\n&lt;li&gt;Every Facility is Unique&lt;/li&gt;\n&lt;li
 &gt;Keys To Successful Facility Protection &amp;bull\; Comprehensive Design&lt;/li&gt;\
 n&lt;/ul&gt;&lt;br /&gt;&lt;br /&gt;Agenda: &lt;br /&gt;&lt;table width=&quot;0&quot;&gt;\n&lt;tbody&gt;\n&lt;tr&gt;\n&lt;td widt
 h=&quot;611&quot;&gt;\n&lt;p&gt;12:00PM&amp;nbsp\;&amp;nbsp\;&amp;nbsp\;&amp;nbsp\; Presentation&lt;/p&gt;\n&lt;p&gt;12:5
 0PM&amp;nbsp\;&amp;nbsp\;&amp;nbsp\;&amp;nbsp\; Questions&lt;/p&gt;\n&lt;p&gt;1:00PM&amp;nbsp\;&amp;nbsp\;&amp;nbs
 p\;&amp;nbsp\;&amp;nbsp\;&amp;nbsp\; Adjourn&lt;/p&gt;\n&lt;/td&gt;\n&lt;/tr&gt;\n&lt;/tbody&gt;\n&lt;/table&gt;
END:VEVENT
END:VCALENDAR

