BEGIN:VCALENDAR
VERSION:2.0
PRODID:IEEE vTools.Events//EN
CALSCALE:GREGORIAN
BEGIN:VTIMEZONE
TZID:America/New_York
BEGIN:DAYLIGHT
DTSTART:20220313T030000
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
RRULE:FREQ=YEARLY;BYDAY=2SU;BYMONTH=3
TZNAME:EDT
END:DAYLIGHT
BEGIN:STANDARD
DTSTART:20221106T010000
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
RRULE:FREQ=YEARLY;BYDAY=1SU;BYMONTH=11
TZNAME:EST
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTAMP:20220913T212133Z
UID:51CCB400-D4FE-45FD-A7F2-37DF0DF977A4
DTSTART;TZID=America/New_York:20220909T150000
DTEND;TZID=America/New_York:20220909T163000
DESCRIPTION:High voltage direct current (HVDC) cables with extruded insulat
 ion system were introduced in 1998. Since then\, this technology has been 
 growing rapidly with many installations that are today operational at volt
 ages up to 320 kV. With fast developments during the last few years\, extr
 uded DC cable systems for operation voltages as high as 640 kV are now com
 mercially available. Due to the importance of DC conductivity in the distr
 ibution of electrical field across the cable insulation\, a good understan
 ding of the DC conduction physics is of key importance to the design of ro
 bust HVDC cables. Currently\, cross-linked polyethylene (XLPE) is the domi
 nating material used in the insulation system of extruded DC cables. Since
  XLPE includes peroxide decomposition products (PDP)\, understanding their
  role on conduction behavior of the insulation system has been of great in
 terest. The PDP and other chemical species can move in the system through 
 diffusion which makes the characterization of cable insulation more challe
 nging. Besides\, like other semi-crystalline polymers\, morphology of the 
 XLPE evolves with temperature and over time. These changes in the material
  pose challenges to their electrical characterization by requiring stringe
 nt control of parameters during preparation\, storage\, and measurement. I
 n this work\, electrical characterization techniques relevant to polymeric
  insulation materials are discussed highlighting their applications and li
 mitations.\n\nBldg: University of Waterloo\, EIT-3151\, Waterloo\, Ontario
 \, Canada
LOCATION:Bldg: University of Waterloo\, EIT-3151\, Waterloo\, Ontario\, Can
 ada
ORGANIZER:sahar.azad@uwaterloo.ca
SEQUENCE:2
SUMMARY:High Voltage DC Cable Insulation Characterization
URL;VALUE=URI:https://events.vtools.ieee.org/m/323431
X-ALT-DESC:Description: &lt;br /&gt;&lt;p&gt;High voltage direct current (HVDC) cables 
 with extruded insulation system were introduced in 1998. Since then\, this
  technology has been growing rapidly with many installations that are toda
 y operational at voltages up to 320 kV. With fast developments during the 
 last few years\, extruded DC cable systems for operation voltages as high 
 as 640 kV are now commercially available. Due to the importance of DC cond
 uctivity in the distribution of electrical field across the cable insulati
 on\, a good understanding of the DC conduction physics is of key importanc
 e to the design of robust HVDC cables. Currently\, cross-linked polyethyle
 ne (XLPE) is the dominating material used in the insulation system of extr
 uded DC cables. Since XLPE includes peroxide decomposition products (PDP)\
 , understanding their role on conduction behavior of the insulation system
  has been of great interest. The PDP and other chemical species can move i
 n the system through diffusion which makes the characterization of cable i
 nsulation more challenging. Besides\, like other semi-crystalline polymers
 \, morphology of the XLPE evolves with temperature and over time. These ch
 anges in the material pose challenges to their electrical characterization
  by requiring stringent control of parameters during preparation\, storage
 \, and measurement. In this work\, electrical characterization techniques 
 relevant to polymeric insulation materials are discussed highlighting thei
 r applications and limitations.&lt;/p&gt;
END:VEVENT
END:VCALENDAR

