DESCRIPTION:Regulating power transmission within the central locations of t
 he city\, the grid station is a conventional unit functioning one 132 kV o
 utdoor yard stepping down power to two indoor 11 kV yards to deliver power
  among KDA\, Jail Road\, Gulistan-e-Johar\, Aga Khan University Hospital e
 tc. This grid receives the necessary power to supply load centres via a to
 tal of 6 inbound transmission lines\, including a 220 kV line\, coming fro
 m other grids.\n\nThe enthusiastic undergraduates along with faculty noted
  AIS (Air Insulated Switchgear) &amp; GIS (Gas Insulated Switchgear) installed
 . At the grid yard\, bus couplers are used to make &amp; break connections dur
 ing service or abnormality detected by relays. Furthermore\, circuit break
 ers undergo a breaker test to ensure that their contacts break simultaneou
 sly within a timeframe of 10 milliseconds to achieve total fault isolation
 .\n\nStudents were able to comprehend the off-load protection carried by i
 solators in the grid as well as the breakdown of K-Electric’s busbar sch
 eme. Reserved busbars along with main busbars were utilised to deliver pow
 er to priority loads whereas the load management is being governed at the 
 control office inside the 11kV yard. The demonstrators The line managers d
 epicted the curiosity of students over the relay test blocks equipped unde
 r the panels. These test blocks are being simulated at faulty conditions i
 solated from real-time values for setting tripping time &amp; magnitudes for s
 afety of personnel &amp; equipment comprising of the grid in a nutshell.\n\nCo
 -sponsored by: K-Electric\n\nAgenda: \nThe primary aim was to nurture the 
 young minds with power systems domain &amp; impart technical knowledge for the
  fieldwork. The core deliverables envisioned by IEEE PES add value creatio
 n at such occurrences. To gauge the hub of electrical unit and power dispa
 tch in Karachi\, a visit was initiated at the only vertically-integrated u
 tility\; K-Electric Gulshan-e-Iqbal Grid Station.\n\nBldg: 132kV Gulshan G
 rid\, Gulshan-e-Iqbal\, K-Electric\, Karachi\, Sindh\, Pakistan
LOCATION:Bldg: 132kV Gulshan Grid\, Gulshan-e-Iqbal\, K-Electric\, Karachi\
 , Sindh\, Pakistan
ORGANIZER:hunainraza@ieee.org
SEQUENCE:0
SUMMARY:K-Electric 132kV Gulshan Grid Visit
URL;VALUE=URI:https://events.vtools.ieee.org/m/348150
X-ALT-DESC:Description: &lt;br /&gt;&lt;p&gt;Regulating power transmission within the c
 entral locations of the city\, the grid station is a conventional unit fun
 ctioning one 132 kV outdoor yard stepping down power to two indoor 11 kV y
 ards to deliver power among KDA\, Jail Road\, Gulistan-e-Johar\, Aga Khan 
 University Hospital etc. This grid receives the necessary power to supply 
 load centres via a total of 6 inbound transmission lines\, including a 220
  kV line\, coming from other grids.&lt;/p&gt;\n&lt;p&gt;The enthusiastic undergraduate
 s along with faculty noted AIS &lt;em&gt;(Air Insulated Switchgear)&lt;/em&gt; &amp;amp\; 
 GIS &lt;em&gt;(Gas Insulated Switchgear) &lt;/em&gt;installed. At the grid yard\, bus 
 couplers are used to make &amp;amp\; break connections during service or abnor
 mality detected by relays. Furthermore\, circuit breakers undergo a breake
 r test to ensure that their contacts break simultaneously within a timefra
 me of 10 milliseconds to achieve total fault isolation.&lt;/p&gt;\n&lt;p&gt;Students w
 ere able to comprehend the off-load protection carried by isolators in the
  grid as well as the breakdown of K-Electric&amp;rsquo\;s busbar scheme. Reser
 ved busbars along with main busbars were utilised to deliver power to prio
 rity loads whereas the load management is being governed at the control of
 fice inside the 11kV yard. The demonstrators The line managers depicted th
 e curiosity of students over the relay test blocks equipped under the pane
 ls. These test blocks are being simulated at faulty conditions isolated fr
 om real-time values for setting tripping time &amp;amp\; magnitudes for safety
  of personnel &amp;amp\; equipment comprising of the grid in a nutshell.&lt;/p&gt;&lt;b
 r /&gt;&lt;br /&gt;Agenda: &lt;br /&gt;&lt;p&gt;The primary aim was to nurture the young minds 
 with power systems domain &amp;amp\; impart technical knowledge for the fieldw
 ork. The core deliverables envisioned by IEEE PES add value creation at su
 ch occurrences. To gauge the hub of electrical unit and power dispatch in 
 Karachi\, a visit was initiated at the only vertically-integrated utility\
 ; &lt;strong&gt;K-Electric Gulshan-e-Iqbal Grid &lt;/strong&gt;Station.&lt;/p&gt;