BEGIN:VCALENDAR
VERSION:2.0
PRODID:IEEE vTools.Events//EN
CALSCALE:GREGORIAN
BEGIN:VTIMEZONE
TZID:US/Eastern
BEGIN:DAYLIGHT
DTSTART:20230312T030000
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
RRULE:FREQ=YEARLY;BYDAY=2SU;BYMONTH=3
TZNAME:EDT
END:DAYLIGHT
BEGIN:STANDARD
DTSTART:20231105T010000
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
RRULE:FREQ=YEARLY;BYDAY=1SU;BYMONTH=11
TZNAME:EST
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTAMP:20230504T153238Z
UID:E880FC81-2D9E-47ED-A1CB-C1CFE35CB17F
DTSTART;TZID=US/Eastern:20230428T090000
DTEND;TZID=US/Eastern:20230428T140000
DESCRIPTION:Part 1) Partial Discharge – Causes\, Effects\, and Online Det
 ection Methods\n\n- What is partial discharge (PD) and why do we care?\n- 
 Causes of partial discharge\n- Effects of PD – examples\n- Side effects 
 and symptoms of PD\n- Online detection methods\n- Ultrasonic monitoring\n-
  Transient Earth Voltage measurement\n- UHF Radiation detection\n- Cable s
 hield HFCT\n\n- Periodic surveying\n- Interpreting results\n- Full time mo
 nitoring\n\nPart 2) Infrared Thermography for Electrical System Maintenanc
 e - How to Ensure Accuracy\, Safety\, and Reliability\n\nOnce an obscure t
 echnology\, infrared thermography has become a common test technique for i
 nspecting operating electrical systems and equipment. Although today’s t
 hermal imaging equipment is relatively easy to use\, performing an accurat
 e infrared inspection is more than simply ‘pointing and shooting’ a th
 ermal imager. Ensuring success requires a trained operator\, the correct e
 quipment\, and knowledge of temperature limits for inspected equipment. Th
 is course will cover the key elements necessary for safely performing accu
 rate infrared inspections\, prioritizing exceptions\, and techniques for d
 etermining if electrical equipment is operating within design temperature 
 limits.\n\nThis course is a must for anyone who performs infrared inspecti
 ons of electrical systems for the purpose of Preventive/Predictive Mainten
 ance or Quality Assurance.\n\nLearning outcomes\n\n- recognize various use
 s of infrared imaging for electrical systems\n- select thermal imaging equ
 ipment appropriate for any infrared inspection\n- improve inspection findi
 ngs and temperature measurement accuracy\n- prioritize exceptions utilizin
 g published engineering standards\n- apply temperature limits to operating
  electrical components\n- ensure compliance with published standards for i
 nfrared inspection reports\n\nCo-sponsored by: ken oexle\n\nSpeaker(s): Jo
 rge\, Jim\n\nAgenda: \nThe seminar fee includes lunch\, refreshments and h
 andouts. Non-members joining IEEE within 30 days of the seminar will be re
 bated 50% of the IEEE registration charge.\n\nFour hours of instruction wi
 ll be provided. If desired\, IEEE Continuing Education Units (0.4 CEUs) wi
 ll be offered for this course - a small fee of $55 will be required for pr
 ocessing.\n\nPlease pay attention to the “Registration Fee” and choose
  the appropriate choice either with or without CEUs.\n\nCEU Evaluation For
 m can be found at: [IEEE Power &amp; Energy North Jersey Continuing Education 
 Certificates - IEEE Innovation at Work](https://innovationatwork.ieee.org/
 ieee-pes-northjersey-certificates/)\n\nAt this time\, our attendance is be
 ing limited to fifty (50). Please only register if you know you are going 
 to attend\, and you must be registered to participate.\n\nRoom: Auditorium
 \, Bldg: PSE&amp;G - Hadley Road Facility\, 4000 Hadley Road\, South Plainfiel
 d\, New Jersey\, United States\, 07080 
LOCATION:Room: Auditorium\, Bldg: PSE&amp;G - Hadley Road Facility\, 4000 Hadle
 y Road\, South Plainfield\, New Jersey\, United States\, 07080 
ORGANIZER:RWQuade@ieee.org
SEQUENCE:1
SUMMARY:Partial Discharge – Causes\, Effects\, and Online Detection Metho
 ds &amp; Infrared Thermography for Electrical System Maintenance
URL;VALUE=URI:https://events.vtools.ieee.org/m/360139
X-ALT-DESC:Description: &lt;br /&gt;&lt;p&gt;&lt;strong&gt;Part 1) Partial Discharge &amp;ndash\;
  Causes\, Effects\, and Online Detection Methods&lt;/strong&gt;&lt;/p&gt;\n&lt;ul&gt;\n&lt;li&gt;W
 hat is partial discharge (PD) and why do we care?&lt;/li&gt;\n&lt;li&gt;Causes of part
 ial discharge&lt;/li&gt;\n&lt;li&gt;Effects of PD &amp;ndash\; examples&lt;/li&gt;\n&lt;li&gt;Side eff
 ects and symptoms of PD&lt;/li&gt;\n&lt;li&gt;Online detection methods\n&lt;ul&gt;\n&lt;li&gt;Ultr
 asonic monitoring&lt;/li&gt;\n&lt;li&gt;Transient Earth Voltage measurement&lt;/li&gt;\n&lt;li&gt;
 UHF Radiation detection&lt;/li&gt;\n&lt;li&gt;Cable shield HFCT&lt;/li&gt;\n&lt;/ul&gt;\n&lt;/li&gt;\n&lt;l
 i&gt;Periodic surveying&lt;/li&gt;\n&lt;li&gt;Interpreting results&lt;/li&gt;\n&lt;li&gt;Full time mo
 nitoring&lt;/li&gt;\n&lt;/ul&gt;\n&lt;p&gt;&amp;nbsp\;&lt;/p&gt;\n&lt;p&gt;&lt;strong&gt;Part 2)&amp;nbsp\;&lt;/strong&gt;&lt;s
 trong&gt;Infrared Thermography for Electrical System Maintenance -&amp;nbsp\;&lt;/st
 rong&gt;&lt;strong&gt;How to Ensure Accuracy\, Safety\, and Reliability&lt;/strong&gt;&lt;/p
 &gt;\n&lt;p&gt;Once an obscure technology\, infrared thermography has become a comm
 on test technique for inspecting operating electrical systems and equipmen
 t.&amp;nbsp\; Although today&amp;rsquo\;s thermal imaging equipment is relatively 
 easy to use\, performing an accurate infrared inspection is more than simp
 ly &lt;em&gt;&amp;lsquo\;pointing and shooting&amp;rsquo\; &lt;/em&gt;a thermal imager.&amp;nbsp\;
  Ensuring success requires a trained operator\, the correct equipment\, an
 d knowledge of temperature limits for inspected equipment.&amp;nbsp\; This cou
 rse will cover the key elements necessary for safely performing accurate i
 nfrared inspections\, prioritizing exceptions\, and techniques for determi
 ning if electrical equipment is operating within design temperature limits
 .&lt;/p&gt;\n&lt;p&gt;This course is a must for anyone who performs infrared inspectio
 ns of electrical systems for the purpose of Preventive/Predictive Maintena
 nce or Quality Assurance.&lt;/p&gt;\n&lt;p&gt;&lt;strong&gt;Learning outcomes&lt;/strong&gt;&lt;/p&gt;\n
 &lt;ul&gt;\n&lt;li&gt;recognize various uses of infrared imaging for electrical system
 s&lt;/li&gt;\n&lt;li&gt;select thermal imaging equipment appropriate for any infrared 
 inspection&lt;/li&gt;\n&lt;li&gt;improve inspection findings and temperature measureme
 nt accuracy&lt;/li&gt;\n&lt;li&gt;prioritize exceptions utilizing published engineerin
 g standards&lt;/li&gt;\n&lt;li&gt;apply temperature limits to operating electrical com
 ponents&lt;/li&gt;\n&lt;li&gt;ensure compliance with published standards for infrared 
 inspection reports &amp;nbsp\;&lt;/li&gt;\n&lt;/ul&gt;&lt;br /&gt;&lt;br /&gt;Agenda: &lt;br /&gt;&lt;p&gt;The sem
 inar fee includes lunch\, refreshments and handouts.&amp;nbsp\; Non-members jo
 ining IEEE within 30 days of the seminar will be rebated 50% of the IEEE r
 egistration charge.&lt;/p&gt;\n&lt;p&gt;Four hours of instruction will be provided.&amp;nb
 sp\; If desired\, IEEE Continuing Education Units (0.4 CEUs) will be offer
 ed for this course - a small fee of $55 will be required for processing.&lt;/
 p&gt;\n&lt;p&gt;Please pay attention to the &amp;ldquo\;Registration Fee&amp;rdquo\; and ch
 oose the appropriate choice either with or without CEUs.&lt;/p&gt;\n&lt;p&gt;CEU Evalu
 ation Form can be found at: &lt;a href=&quot;https://innovationatwork.ieee.org/iee
 e-pes-northjersey-certificates/&quot;&gt;IEEE Power &amp;amp\; Energy North Jersey Con
 tinuing Education Certificates - IEEE Innovation at Work&lt;/a&gt;&lt;/p&gt;\n&lt;p&gt;&lt;span
  style=&quot;background-color: #fbeeb8\; color: #e03e2d\;&quot;&gt;At this time\, our a
 ttendance is being limited to fifty (50).&amp;nbsp\; Please only register if y
 ou know you are going to attend\, and you must be registered to participat
 e.&lt;/span&gt;&lt;/p&gt;
END:VEVENT
END:VCALENDAR

