DESCRIPTION:Application of VSC transmission with overhead transmission line
 s is a relatively recent application\, particularly with MMC converters. A
 n overhead transmission line is prone to faults caused by environmental ac
 tivity such as lightning which can be cleared and restarted. There are dif
 ferent configurations for MMC converters which include various monopole an
 d bipole arrangements that can be with half bridge or full bridge submodul
 es. The DC transmission line will invariably be connected through one or m
 ore cable sections as well. The issues associated with rapid restart follo
 wing a lightning fault will be discussed. There is also the possibility th
 at the overhead DC transmission line will be coupled to a AC line\, either
  on the same tower or the same way-leave. The impact such fundamental coup
 ling has on the VSC system performance and ways to minimize adverse impact
 s will be presented.\n\nThis is a free to attend event\, but event registr
 ation is required for admission. Follow the registeration link detailed be
 low on this page.\n\nThis event is organised by the University of Birmingh
 am and technically sponsored by the UK &amp; Ireland PES Chapter.\n\nSpeaker(s
 ): Dennis Woodford\, \, Dennis Woodford\, \n\nRoom: NG16\, Bldg: Gisbert K
 app Building\, 52 Pritchatts Road\, University of Birmingham\, Birmingham\
 , England\, United Kingdom\, B15 2SA
LOCATION:Room: NG16\, Bldg: Gisbert Kapp Building\, 52 Pritchatts Road\, Un
 iversity of Birmingham\, Birmingham\, England\, United Kingdom\, B15 2SA
ORGANIZER:X.P.Zhang@bham.ac.uk
SEQUENCE:1
SUMMARY:Seminar: The Challenge of Overhead Line Faults with MMC HVDC Transm
 ission
URL;VALUE=URI:https://events.vtools.ieee.org/m/43943
X-ALT-DESC:Description: &lt;br /&gt;&lt;p&gt;Application of VSC transmission with overh
 ead transmission lines is a relatively recent application\, particularly w
 ith MMC converters. An overhead transmission line is prone to faults cause
 d by environmental activity such as lightning which can be cleared and res
 tarted. There are different configurations for MMC converters which includ
 e various monopole and bipole arrangements that can be with half bridge or
  full bridge submodules. The DC transmission line will invariably be conne
 cted through one or more cable sections as well. The issues associated wit
 h rapid restart following a lightning fault will be discussed. There is al
 so the possibility that the overhead DC transmission line will be coupled 
 to a AC line\, either on the same tower or the same way-leave. The impact 
 such fundamental coupling has on the VSC system performance and ways to mi
 nimize adverse impacts will be presented.&lt;/p&gt;\n&lt;p&gt;This is a free to attend
  event\, but event registration is required&amp;nbsp\;for admission. Follow th
 e registeration link detailed below on this page.&lt;/p&gt;\n&lt;p&gt;This&amp;nbsp\;event
  is organised by the University of Birmingham and technically sponsored by
  the UK &amp;amp\; Ireland PES Chapter.&lt;/p&gt;