BEGIN:VCALENDAR
VERSION:2.0
PRODID:IEEE vTools.Events//EN
CALSCALE:GREGORIAN
BEGIN:VTIMEZONE
TZID:America/New_York
BEGIN:DAYLIGHT
DTSTART:20260308T030000
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
RRULE:FREQ=YEARLY;BYDAY=2SU;BYMONTH=3
TZNAME:EDT
END:DAYLIGHT
BEGIN:STANDARD
DTSTART:20261101T010000
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
RRULE:FREQ=YEARLY;BYDAY=1SU;BYMONTH=11
TZNAME:EST
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTAMP:20261022T203106Z
UID:169735F3-B23B-4ABF-969E-2A567C226BDB
DTSTART;TZID=America/New_York:20261022T150000
DTEND;TZID=America/New_York:20261022T160000
DESCRIPTION:[][] []\n\nIEEE Northern Canada Section Jt. chapter PES/IAS is 
 hosting the technical webinar on &quot;From Complexity to Consistency: Reframin
 g Fault Response Requirements for Inverter-Based Resources&quot; presented by D
 r. Dr. Bogdan Kasztenny.\n\nAdditional Note:\n\n- IEEE PDH attendance cert
 ificate will be provided for $10 CAD. Please fill out evaluation form afte
 r the webinar to receive the certificate.\n\nSpeaker(s): Dr. Bogdan Kaszte
 nny\, \n\nAgenda: \nDate: 22-October-2026\n\nTime: 03:00 PM to 04:00 PM ET
 \n\nAbstract:\n\nThe fault response of inverter-based resources (IBRs) rem
 ains one of the most significant challenges in modern power systems and a 
 major focus of standardization efforts. Despite years of work\, protection
  engineers still face uncertainty regarding IBR behavior during faults. Pr
 otection design near IBRs currently relies heavily on detailed models and 
 simulation studies. This approach is fragile because changes in user-adjus
 table settings or firmware can invalidate prior studies and require costly
  redesign. While model-based design was initially necessary\, it is not a 
 sustainable long-term solution.\n\nThis presentation introduces a new fram
 ework for defining IBR fault-response requirements in high-voltage network
 s. The approach is simple\, time-domain based\, and grounded in physical p
 rinciples. It emphasizes fast response\, current-voltage consistency\, and
  incremental currents\, including negative-sequence incremental current. W
 e show that an IBR can be designed to behave as a static current source be
 hind a virtual shunt reactor\, producing currents compatible with establis
 hed protection principles. The method requires no explicit negative-sequen
 ce controller while still delivering instantaneous and correct negative-se
 quence current.\n\nThe proposed framework promotes network homogeneity and
  preserves expected voltage-current relationships\, allowing protection fu
 nctions to operate reliably without detailed IBR models. It reduces the ne
 ed for extensive modeling\, supports both conventional and incremental-qua
 ntity-based protection elements\, and imposes no additional cost or comple
 xity on manufacturers. By constraining IBR fault response\, it provides a 
 practical path toward standardization\, improved protection reliability\, 
 and reduced engineering effort in networks with high IBR penetration.\n\nS
 chedule:\n\n03:00 – 03:02 PM ET: Greetings to attendees and Speaker intr
 oduction\n\n03:03 – 03:50 PM ET: Technical presentation by the speaker\n
 \n03:51 – 04:00 PM ET: Questions and Answers\n\nLocation:\n\nVirtual onl
 y. WebEx meeting room.\n\nVirtual: https://events.vtools.ieee.org/m/570152
LOCATION:Virtual: https://events.vtools.ieee.org/m/570152
ORGANIZER:mithil.acharya@ieee.org
SEQUENCE:40
SUMMARY:From Complexity to Consistency: Reframing Fault Response Requiremen
 ts for Inverter-Based Resources
URL;VALUE=URI:https://events.vtools.ieee.org/m/570152
X-ALT-DESC:Description: &lt;br /&gt;&lt;p class=&quot;xmsonormal&quot; style=&quot;text-align: cent
 er\;&quot;&gt;&lt;span lang=&quot;EN-US&quot; style=&quot;font-size: 11.0pt\; mso-ansi-language: EN-
 US\;&quot;&gt;&amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbs
 p\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &lt;img src=&quot;https://even
 ts.vtools.ieee.org/vtools_ui/media/display/08165337-b241-43ce-b4ab-5427a34
 3a1e9&quot; alt=&quot;&quot; width=&quot;171&quot; height=&quot;119&quot;&gt;&lt;img style=&quot;float: left\;&quot; src=&quot;htt
 ps://events.vtools.ieee.org/vtools_ui/media/display/e45eeb71-4d5e-4302-90d
 c-25c2c3f66c9e&quot; alt=&quot;&quot; width=&quot;250&quot; height=&quot;129&quot;&gt;&amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;n
 bsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbs
 p\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\;&lt;img src=&quot;https://events.vtools.ieee.org/vtools
 _ui/media/display/82b6b239-f636-4e91-b750-7c9d4a3385ea&quot; alt=&quot;&quot; width=&quot;376&quot;
  height=&quot;117&quot;&gt;&lt;/span&gt;&lt;/p&gt;\n&lt;p class=&quot;xmsonormal&quot;&gt;&amp;nbsp\;&lt;/p&gt;\n&lt;p class=&quot;xm
 sonormal&quot;&gt;&amp;nbsp\;&lt;/p&gt;\n&lt;p class=&quot;xmsonormal&quot; style=&quot;text-align: justify\;&quot;
 &gt;&lt;span lang=&quot;EN-US&quot; style=&quot;font-size: 11.0pt\; mso-ansi-language: EN-US\;&quot;
 &gt;IEEE Northern Canada Section Jt. chapter PES/IAS is hosting the technical
  webinar on &quot;From Complexity to Consistency: Reframing Fault Response Requ
 irements for Inverter-Based Resources&quot; presented by Dr. Dr. Bogdan Kaszten
 ny&lt;span lang=&quot;EN-US&quot;&gt;.&amp;nbsp\;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;\n&lt;p class=&quot;xmsonormal&quot;&gt;&lt;sp
 an lang=&quot;EN-US&quot; style=&quot;font-size: 11.0pt\; mso-ansi-language: EN-US\;&quot;&gt;Add
 itional Note:&lt;/span&gt;&lt;/p&gt;\n&lt;ul&gt;\n&lt;li class=&quot;xmsonormal&quot;&gt;&lt;span lang=&quot;EN-US&quot; 
 style=&quot;font-size: 11.0pt\; mso-ansi-language: EN-US\;&quot;&gt;IEEE PDH attendance
  certificate will be provided for $10 CAD.&amp;nbsp\; Please fill out evaluati
 on form after the webinar to receive the certificate.&lt;/span&gt;&lt;/li&gt;\n&lt;/ul&gt;&lt;b
 r /&gt;&lt;br /&gt;Agenda: &lt;br /&gt;&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;text-decoration:
  underline\;&quot;&gt;&lt;strong&gt;Date:&lt;/strong&gt;&lt;/span&gt; 22-October-2026&lt;/p&gt;\n&lt;p class=
 &quot;MsoNormal&quot;&gt;&lt;span style=&quot;text-decoration: underline\;&quot;&gt;&lt;strong&gt;Time:&lt;/stro
 ng&gt;&lt;/span&gt; 03:00 PM to 04:00 PM ET&lt;/p&gt;\n&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;
 text-decoration: underline\;&quot;&gt;&lt;strong&gt;Abstract:&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;\n&lt;p cl
 ass=&quot;MsoNormal&quot; style=&quot;text-align: justify\;&quot;&gt;The fault response of invert
 er-based resources (IBRs) remains one of the most significant challenges i
 n modern power systems and a major focus of standardization efforts. Despi
 te years of work\, protection engineers still face uncertainty regarding I
 BR behavior during faults. Protection design near IBRs currently relies he
 avily on detailed models and simulation studies. This approach is fragile 
 because changes in user-adjustable settings or firmware can invalidate pri
 or studies and require costly redesign. While model-based design was initi
 ally necessary\, it is not a sustainable long-term solution.&lt;/p&gt;\n&lt;p class
 =&quot;MsoNormal&quot; style=&quot;text-align: justify\;&quot;&gt;This presentation introduces a 
 new framework for defining IBR fault-response requirements in high-voltage
  networks. The approach is simple\, time-domain based\, and grounded in ph
 ysical principles. It emphasizes fast response\, current-voltage consisten
 cy\, and incremental currents\, including negative-sequence incremental cu
 rrent. We show that an IBR can be designed to behave as a static current s
 ource behind a virtual shunt reactor\, producing currents compatible with 
 established protection principles. The method requires no explicit negativ
 e-sequence controller while still delivering instantaneous and correct neg
 ative-sequence current.&lt;/p&gt;\n&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justi
 fy\;&quot;&gt;The proposed framework promotes network homogeneity and preserves ex
 pected voltage-current relationships\, allowing protection functions to op
 erate reliably without detailed IBR models. It reduces the need for extens
 ive modeling\, supports both conventional and incremental-quantity-based p
 rotection elements\, and imposes no additional cost or complexity on manuf
 acturers. By constraining IBR fault&amp;nbsp\;response\, it provides a practic
 al path toward standardization\, improved protection reliability\, and red
 uced engineering effort in networks with high IBR penetration.&lt;/p&gt;\n&lt;p cla
 ss=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;text-decoration: underline\;&quot;&gt;&lt;strong&gt;Schedule
 :&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;\n&lt;p class=&quot;MsoNormal&quot;&gt;03:00 &amp;ndash\; 03:02 PM ET: Gr
 eetings to attendees and Speaker introduction&lt;/p&gt;\n&lt;p class=&quot;MsoNormal&quot;&gt;03
 :03 &amp;ndash\; 03:50 PM ET: Technical presentation by the speaker&lt;/p&gt;\n&lt;p cl
 ass=&quot;MsoNormal&quot;&gt;03:51 &amp;ndash\; 04:00 PM ET: Questions and Answers&lt;/p&gt;\n&lt;p 
 class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;text-decoration: underline\;&quot;&gt;&lt;strong&gt;Locat
 ion:&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;\n&lt;p class=&quot;MsoNormal&quot;&gt;Virtual only. WebEx meeting
  room.&lt;/p&gt;
END:VEVENT
END:VCALENDAR

