BEGIN:VCALENDAR
VERSION:2.0
PRODID:IEEE vTools.Events//EN
CALSCALE:GREGORIAN
BEGIN:VTIMEZONE
TZID:America/Los_Angeles
BEGIN:DAYLIGHT
DTSTART:20260308T030000
TZOFFSETFROM:-0800
TZOFFSETTO:-0700
RRULE:FREQ=YEARLY;BYDAY=2SU;BYMONTH=3
TZNAME:PDT
END:DAYLIGHT
BEGIN:STANDARD
DTSTART:20261101T010000
TZOFFSETFROM:-0700
TZOFFSETTO:-0800
RRULE:FREQ=YEARLY;BYDAY=1SU;BYMONTH=11
TZNAME:PST
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTAMP:20260927T183609Z
UID:321B14C3-EEEF-422E-9DB6-2C4FD383C272
DTSTART;TZID=America/Los_Angeles:20261012T153000
DTEND;TZID=America/Los_Angeles:20261012T161000
DESCRIPTION:Packaging of Multimodal Sensors with Backscattering Telemetry f
 or Health-Monitoring\n\nDr. Markondeya Raj Pulgurtha\, Florida Internation
 al University\n\nDate: October 12\, 2026\n\nTime: 3:30 pm to 4:10pm\n\nLoc
 ation: PSU Vernier Science Center room 105\n\nWearable sensors co-packaged
  with sensor\, signal mixer and telemetry components are developed to prov
 ide a multimodal cardiovascular monitoring platform with good signal sensi
 tivity and data telemetry. In vitro phantom validation and benchmarking ag
 ainst current multimodal sensors have been used to demonstrate NIRS\, ECG 
 and SCG functionality. Wireless data transfer with near-field inductive li
 nk is developed and characterized. Low-frequency (40-200 kHz) telemetry wi
 th multiferroic transducers are also developed to enable efficient wireles
 s power telemetry and sensor control through programmable static magnetic 
 field generation. The system achieves robust power transmission at distanc
 es exceeding 3 cm by operating below 300 kHz\, thereby minimizing tissue a
 bsorption\, heat generation\, and electromagnetic losses. The resulting pa
 tch can therefore function as a disposable\, batteryless sensing layer wit
 h minimal embedded electronics. This architecture establishes a scalable p
 ath toward continuous low-burden cardiac monitoring with extremely low pow
 er operation and manufacturable flexible sensor integration.\n\nCo-sponsor
 ed by: Portland Sate University Physics Dept.\n\nSpeaker(s): Dr. P M Raj\,
  \n\nAgenda: \n3:30 pm Introduction\n\n4:10 pm Adjourn\n\nRoom: 105\, Bldg
 : Vernier Science Center\, Portland State University\, 1025 SW Mill Street
 \, Portland\, Oregon\, United States\, 97201
LOCATION:Room: 105\, Bldg: Vernier Science Center\, Portland State Universi
 ty\, 1025 SW Mill Street\, Portland\, Oregon\, United States\, 97201
ORGANIZER:e.perkins@ieee.org
SEQUENCE:5
SUMMARY:Packaging of Multimodal Sensors with Backscattering Telemetry for H
 ealth-Monitoring
URL;VALUE=URI:https://events.vtools.ieee.org/m/580293
X-ALT-DESC:Description: &lt;br /&gt;&lt;h2&gt;Packaging of Multimodal Sensors with Back
 scattering Telemetry for Health-Monitoring&lt;/h2&gt;\n&lt;p&gt;&lt;strong&gt;&lt;span style=&quot;f
 ont-size: 14pt\;&quot;&gt;Dr. Markondeya Raj Pulgurtha\, Florida International Uni
 versity&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;\n&lt;p&gt;&lt;strong&gt;&lt;span style=&quot;font-size: 14pt\;&quot;&gt;Da
 te: October 12\, 2026&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;\n&lt;p&gt;&lt;strong&gt;&lt;span style=&quot;font-si
 ze: 14pt\;&quot;&gt;Time: 3:30 pm to 4:10pm&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;\n&lt;p&gt;&lt;strong&gt;&lt;span 
 style=&quot;font-size: 14pt\;&quot;&gt;Location: PSU Vernier Science Center room 105&lt;/s
 pan&gt;&lt;/strong&gt;&lt;/p&gt;\n&lt;p style=&quot;text-align: justify\;&quot;&gt;Wearable sensors co-pa
 ckaged with sensor\, signal mixer and telemetry components are developed t
 o provide a multimodal cardiovascular monitoring platform with good signal
  sensitivity and data telemetry. In vitro phantom validation and benchmark
 ing against current multimodal sensors have been used to demonstrate NIRS\
 , ECG and SCG functionality. Wireless data transfer with near-field induct
 ive link is developed and characterized. Low-frequency (40-200 kHz) teleme
 try with multiferroic transducers are also developed to enable efficient w
 ireless power telemetry and sensor control through programmable static mag
 netic field generation. The system achieves robust power transmission at d
 istances exceeding 3 cm by operating below 300 kHz\, thereby minimizing ti
 ssue absorption\, heat generation\, and electromagnetic losses. The result
 ing patch can therefore function as a disposable\, batteryless sensing lay
 er with minimal embedded electronics. This architecture establishes a scal
 able path toward continuous low-burden cardiac monitoring with extremely l
 ow power operation and manufacturable flexible sensor integration.&lt;/p&gt;\n&lt;p
  style=&quot;text-align: justify\;&quot;&gt;&amp;nbsp\;&lt;/p&gt;&lt;br /&gt;&lt;br /&gt;Agenda: &lt;br /&gt;&lt;p&gt;3:3
 0 pm Introduction&lt;/p&gt;\n&lt;p&gt;4:10 pm Adjourn&lt;/p&gt;\n&lt;p&gt;&amp;nbsp\;&lt;/p&gt;
END:VEVENT
END:VCALENDAR

