BEGIN:VCALENDAR
VERSION:2.0
PRODID:IEEE vTools.Events//EN
CALSCALE:GREGORIAN
BEGIN:VTIMEZONE
TZID:America/Chicago
BEGIN:DAYLIGHT
DTSTART:20270314T030000
TZOFFSETFROM:-0600
TZOFFSETTO:-0500
RRULE:FREQ=YEARLY;BYDAY=2SU;BYMONTH=3
TZNAME:CDT
END:DAYLIGHT
BEGIN:STANDARD
DTSTART:20261101T010000
TZOFFSETFROM:-0500
TZOFFSETTO:-0600
RRULE:FREQ=YEARLY;BYDAY=1SU;BYMONTH=11
TZNAME:CST
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTAMP:20261015T194423Z
UID:4D2167FB-09F2-4B8F-928F-842E7531BFF8
DTSTART;TZID=America/Chicago:20261119T183100
DTEND;TZID=America/Chicago:20261119T203100
DESCRIPTION:The Chicago Chapter of IEEE EMC Society \, Invites you to our N
 ovember 19\, 2026 meeting.\n\nThe topic of understanding modern EMI Measur
 ement Equipment should be of interest to all EMC practitioners.\n\nAbstrac
 t: Traditionally\, EMI Measurements are performed by spectrum analyzers or
  EMI receivers. Using the FFT-based measurement systems for EMI testing ca
 n reduce test time\, improve the repeatability of EMI tests. While MIL461F
  defines the settings of dwell and sweep time for spectrum analyzers and E
 MI receivers\, MIL461F defines the first-time parameters and requirements 
 for the FFT-based measurement systems.\n\nDuring the presentation the tech
 nological and mathematical background FFT-based measurement according to C
 ISPR 16-1-1/ANSI C63.2 and MIL461 is explained. The requirements of CISPR 
 16-1-1/ANSI C63.2 and MIL461G regarding the implementation as well as the 
 equivalence to a traditional EMI receiver ensure traceability and the same
  test results. The difference between an FFT-analyzer\, a Real-time spectr
 um analyzer and the FFT-based measurement system are explained. Some pitfa
 lls of using scopes with FFT-mode or noncompliant real-time spectrum analy
 zers for EMI testing are explained. Table 2 of MIL461G points out differen
 t parameters regarding the dwell time for stepped scan and FFT-based measu
 rement system. During practical demonstration of the measurement of fluctu
 ating signals\, it is explained why a longer dwell time for FFT-based meas
 urements according to MIL461G is required. Also\, the advantages regarding
  the reproducibility and reduction of test time is shown. In addition to t
 raditional scanning FFT-based measuring instruments also offers new method
 s to visualize and analyzer signals. During the presentation also the usag
 e of spectrogram\, time-domain analysis and complaint Real-time spectrum a
 nalyzer are shown. Applications like the detection of cycles of emissions 
 as well as the identification of sources using correlation methods are sho
 wn. In addition\, the changes given in MIL461H regarding EMI testing is pr
 esented.\n\nSpeaker(s): Dr. Stephan Braun \, \n\nAgenda: \nMeeting Agenda:
 \n\nDinner and Networking 6:30 to 7:00\n\nAnnouncements 7:00 to 7:15\n\nPr
 esentation 7:15 to 8:15\n\nFinal Comments 8:15 to 8:30\n\nDLS Electronic S
 ystems\, Inc.\, 1250 Peterson Dr.\, Wheeling\, Illinois\, United States\, 
 60090
LOCATION:DLS Electronic Systems\, Inc.\, 1250 Peterson Dr.\, Wheeling\, Ill
 inois\, United States\, 60090
ORGANIZER:jblack@dlsemc.com
SEQUENCE:64
SUMMARY:Traditional and FFT-based EMI Measurements according to MIL STD 461
  and RTCA DO160 
URL;VALUE=URI:https://events.vtools.ieee.org/m/584918
X-ALT-DESC:Description: &lt;br /&gt;&lt;p&gt;&lt;span style=&quot;font-size: small\;&quot;&gt;&lt;strong&gt;T
 he Chicago Chapter of IEEE EMC Society \, Invites you to our November 19\,
  2026 meeting.&amp;nbsp\;&amp;nbsp\;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;\n&lt;p&gt;&lt;span style=&quot;font-siz
 e: small\;&quot;&gt;&lt;strong&gt;The topic of understanding modern EMI Measurement Equi
 pment should be of interest to all EMC practitioners.&amp;nbsp\;&lt;/strong&gt;&lt;/spa
 n&gt;&lt;/p&gt;\n&lt;p&gt;&lt;span style=&quot;font-size: small\;&quot;&gt;&lt;strong&gt;&lt;img src=&quot;https://even
 ts.vtools.ieee.org/vtools_ui/media/display/b1adb169-7a8c-468d-88cd-8c8aeb2
 0d3bb&quot;&gt;&lt;img src=&quot;https://events.vtools.ieee.org/vtools_ui/media/display/2d
 7bd7a1-5067-4148-a948-626b69d699f5&quot;&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;\n&lt;p&gt;&lt;span style=&quot;
 font-size: small\;&quot;&gt;&lt;strong&gt;Abstract: Traditionally\, EMI Measurements are
  performed by spectrum analyzers or EMI receivers. Using the FFT-based mea
 surement systems for EMI testing can reduce test time\, improve the repeat
 ability of EMI tests. While MIL461F defines the settings of dwell and swee
 p time for spectrum analyzers and EMI receivers\, MIL461F defines the firs
 t-time parameters and requirements for the FFT-based measurement systems.&lt;
 /strong&gt;&lt;/span&gt;&lt;/p&gt;\n&lt;p&gt;&lt;span style=&quot;font-size: small\;&quot;&gt;&lt;strong&gt;During th
 e presentation the technological and mathematical background FFT-based mea
 surement according to CISPR 16-1-1/ANSI C63.2 and MIL461 is explained. The
  requirements of CISPR 16-1-1/ANSI C63.2 and MIL461G regarding the impleme
 ntation as well as the equivalence to a traditional EMI receiver ensure tr
 aceability and the same test results. The difference between an FFT-analyz
 er\, a Real-time spectrum analyzer and the FFT-based measurement system ar
 e explained. Some pitfalls of using scopes with FFT-mode or noncompliant r
 eal-time spectrum analyzers for EMI testing are explained. Table 2 of MIL4
 61G points out different parameters regarding the dwell time for stepped s
 can and FFT-based measurement system. During practical demonstration of th
 e measurement of fluctuating signals\, it is explained why a longer dwell 
 time for FFT-based measurements according to MIL461G is required. Also\, t
 he advantages regarding the reproducibility and reduction of test time is 
 shown. In addition to traditional scanning FFT-based measuring instruments
  also offers new methods to visualize and analyzer signals. During the pre
 sentation also the usage of spectrogram\, time-domain analysis and complai
 nt Real-time spectrum analyzer are shown. Applications like the detection 
 of cycles of emissions as well as the identification of sources using corr
 elation methods are shown. In addition\, the changes given in MIL461H rega
 rding EMI testing is presented.&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;&lt;br /&gt;&lt;br /&gt;Agenda: &lt;br
  /&gt;&lt;p&gt;&lt;span style=&quot;color: #ee0000\;&quot;&gt;&lt;span style=&quot;font-size: large\;&quot;&gt;&lt;str
 ong&gt;Meeting Agenda:&lt;/strong&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;\n&lt;p&gt;&lt;strong&gt;Dinner and Netw
 orking&amp;nbsp\; &amp;nbsp\; &amp;nbsp\; 6:30 to 7:00&lt;/strong&gt;&lt;/p&gt;\n&lt;p&gt;&lt;strong&gt;Announ
 cements&amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nb
 sp\; 7:00 to 7:15&lt;/strong&gt;&lt;/p&gt;\n&lt;p&gt;&lt;strong&gt;Presentation&amp;nbsp\; &amp;nbsp\; &amp;nb
 sp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp
 \; 7:15 to 8:15&lt;/strong&gt;&lt;/p&gt;\n&lt;p&gt;&lt;strong&gt;Final Comments&amp;nbsp\; &amp;nbsp\; &amp;nb
 sp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\; &amp;nbsp\;8:15 to 8:30&lt;/
 strong&gt;&lt;/p&gt;\n&lt;p&gt;&lt;br&gt;&lt;br&gt;&lt;/p&gt;
END:VEVENT
END:VCALENDAR

