Kohler Live Webinar Series on Backup Power Systems
IEEE Tappan Zee Subsection Joint Meeting with IEEE New York PES/IAS (Power & Energy Society/Industrial Applications Society) Chapter Presents
Virtual Generator "Lunch" and Learn Sessions by Kohler (in Power Since 1920)
When: Occurs every 2 week(s) on Thursday effective 2/18/20210 until 4/29/2021 from 12:20 PM to 1:30 PM Eastern Standard Time.
Where: Microsoft Teams Live Webinar. (Live Audio, Video and Screen sharing)
Ladies and Gentlemen,
In light of our recent need for social isolation, Kohler would like to invite you in this series of live webinars over lunch. The topics below will cover the basics and application of a backup power system (including Backup Generator, ATS, Switchgear etc). The sessions will be happening every 2 weeks for 11 sessions starting July 16th. The topics are listed below in the order intended currently and may change if the need arises.
Requirements for earning PDH credits. Per NY State Education Department (NYSED).
- Registration is required per NYSED: Fill out the form for this series.
- To Register:
Copy this link to a browser: https://forms.office.com/Pages/ResponsePage.aspx?id=Az8tXW4oQ0aPWxBWVgjl-OVXzu1HLYJPjEIptZYSUGpURDdBODBXOFk5WDZUS09KQjlFQldXWE85NS4u
- Attendance is required for the entire session, Please login with your work email to the Microsoft Teams Platform (By your computer app or via Chrome/Edge browser). Without a name/email, we cannot determine attendance for awarding PDH.
- Participation is required by NYSED. There will be questions throughout the presentation to evaluate learning during the courses.
- There will be surveys sent after each course, this is also required by NYSED.
- Courses need to be 60 mins of Educational content. 10 extra minutes is added for any technical issues or Q&A during the sessions.
Course offering, in the order they will happen (these may change, and the invite will be updated accordingly). Filling out the form will help us keep you informed of any changes.
-
Course schedule:
- Generator 101: Basics and Application. (Repeat). 02/18/2021
- ATS 101: Automatic Transfer Switch Basics. (Repeat). 03/04/2021
- ATS 102: Withstand Ratings and Selective Coordination Implications. 03/18/2021
- Paralleling 102: Paralleling Controls, Sequence of Operation and Configurations. 04/01/2021
- Generator Enclosure Basics, Considerations, and Options. 04/15/2021
- Generator Diesel Tank Basics, Considerations, and Options. 04/29/2021
Course Description and learning objectives available upon request.
Please reach out to me directly for any questions or recommendations.
Course Description and learning objectives available upon request.
+1 715-318-2572 United States, Eau Claire (Toll)
Conference ID: 406 371 331#
Local numbers | Reset PIN | Learn more about Teams | Meeting options
Join with a video conferencing device
385348042@t.plcm.vc VTC Conference ID: 1145834914
Alternate VTC dialing instructions
Date and Time
Location
Hosts
Registration
- Date: 18 Mar 2021
- Time: 12:30 PM to 01:30 PM
- All times are (UTC-04:00) Eastern Time (US & Canada)
- Add Event to Calendar
- Microsoft Teams Meeting
- New York, New York
- United States
- Building: Virtual
- Contact Event Host
-
Rumman Kabir, Engineered Solutions Manager, Kohler Power Systems
Mobile: 201 388 9345, Email: Rumman.Kabir@Kohler.com
- Co-sponsored by IEEE PES/IAS Joint Chapter
- Starts 01 February 2021 10:23 AM
- Ends 17 March 2021 10:39 AM
- All times are (UTC-04:00) Eastern Time (US & Canada)
- No Admission Charge
Speakers
Rumman Kabir of Kohler in Power Since 1920
Automatic Transfer Switch (ATS) 101: Basics - 1 PDH (60 minutes)
Automatic transfer switches allow the loads to be fed from either the Utility or backup power sources as its most common use case. In this course we will dive into the basics of automatic transfer switches, their purpose, associated Codes and Standards, types of ATS, and typical installations. This course also touches on ATS controllers, withstand ratings, and power switching methods.
Biography:
Rumman Kabir currently works as a Engineered Solutions Manager at Kohler. Electrical Engineer by Education, he is been working in the backup power industry for more than 12 years. His career evolved from designing the controls system for Generators, ATS, Switchgear to providing Application support to consulting engineers and teams across North America. For the last 6 years he has worked in the Northeastern US states with engineers, end users and local distribution organizations. His specialty includes control systems, paralleling, codes/standards, design best practices etc. Rumman regularly speaks at engineering conferences and seminars on various technical topics.
Kohler is a manufacturer of Diesel and Gas generator sets from 15K-4000KW for backup and prime power applications. 2020 marks 100 years of Kohler in Power Generation. Website: www.kohlerpower.com
Email:
Agenda
Withstand Ratings and Selective Coordination Implications - 1 PDH (60 minutes)
Automatic transfer switches allow the loads to be fed from either the Utility or backup power sources as its most common use case. In this course we will dive into the basics of automatic transfer switches, their purpose, associated Codes and Standards, types of ATS, and typical installations. This course also touches on ATS controllers, withstand ratings, and power switching methods.
Please reach out to me directly for any questions or recommendations.
Rumman Kabir
Engineered Solutions Manager, Kohler Power Systems