Transformer Design and Manufacturing
PES / IAS / LM Joint Meeting
The presentation will be on the Basic of Transformer Design. The presentation will explain how a transformer designer interprets parameters such as MVA, lightning Impulse, Switching impulse, Percentage Impedance supplied by a customer. It will touch on Power rating[MVA], Core, Rated voltages, Insulation Coordination, Short-circuit Impedance, Short-circuit Forces, Loss evaluation, Temperature limits, Cooling, Sound Level .. etc. It will also explain overload and life expectancy of a transformer as well when Delta winding is needed in Wye-Wye connection. The presentation will answer why in North America we like to regulate from low voltage side whereas in Europe regulates from high voltage side. It will include Industry wide manufacturing process to build a transformer in the shop floor. Processes will cover Core Construction, Insulation, Windings, Core and Coil, Processing, Tanking, Testing and Shipping. Some of the hold-points during the processes will be explained as well what a customer should look into while doing factory inspection. The presentation will also cover reconnection both in LV and HV, LTC Tap changer both in tank and separate tank, Lead works.
Date and Time
Location
Hosts
Registration
- Date: 18 Nov 2016
- Time: 02:00 PM UTC to 07:00 PM UTC
-
Add Event to Calendar
- 4000 Hadley Road
- South Plainfield, New Jersey
- United States 07080
- Building: PSE&G - Hadley Road Facility
- Room Number: Auditorium
- Click here for Map
- Contact Event Host
-
- Co-sponsored by Ken Oexle
- Starts 23 September 2016 04:00 AM UTC
- Ends 18 November 2016 01:00 PM UTC
- Admission fee ?
Speakers
Ronnie Minhaz of Transformer Consulting Services Inc.
Transformer Design and Manufacturing
The presentation will be on the Basic of Transformer Design. The presentation will explain how a transformer designer interprets parameters such as MVA, lightning Impulse, Switching impulse, Percentage Impedance supplied by a customer. It will touch on Power rating[MVA], Core, Rated voltages, Insulation Coordination, Short-circuit Impedance, Short-circuit Forces, Loss evaluation, Temperature limits, Cooling, Sound Level .. etc. It will also explain overload and life expectancy of a transformer as well when Delta winding is needed in Wye-Wye connection. The presentation will answer why in North America we like to regulate from low voltage side whereas in Europe regulates from high voltage side. It will include Industry wide manufacturing process to build a transformer in the shop floor. Processes will cover Core Construction, Insulation, Windings, Core and Coil, Processing, Tanking, Testing and Shipping. Some of the hold-points during the processes will be explained as well what a customer should look into while doing factory inspection. The presentation will also cover reconnection both in LV and HV, LTC Tap changer both in tank and separate tank, Lead works.
Biography:
Ronnie Minhaz President Transformer Consulting Services Inc.
Ronnie holds B.Sc. degree in Electrical Engineering from University of Manitoba, Canada. Before founding his own company “Transformer Consulting Services Inc (www.tc-servicesinc.com)”, Ronnie worked as Transformer Designer at Pauwels Canada(Manufacturer), as Equipment Engineer at SNC Lava Lin(EPCM) and Enmax Power(Utility), as Substation Lead Engineer at McGregor Construction(Substation Construction). Ronnie is a registered professional engineer in the province of Alberta, Canada and an IEEE member. Ronnie held various leadership positions at IEEE Section level and a regular member of IEEE PES society
Email:
Address:840-9 Street SW, Suite#907, Calgary, AB, Calgary, AB, Canada, T2P 2T1
Ronnie Minhaz of Transformer Consulting Services Inc.
Transformer Design and Manufacturing
Biography:
Email:
Address:Calgary, AB, Canada
Ronnie Minhaz of Transformer Consulting Services Inc.
Transformer Design and Manufacturing
Biography:
Email:
Address:Calgary, AB, Canada
Ronnie Minhaz of Transformer Consulting Services Inc.
Transformer Design and Manufacturing
Biography:
Email:
Address:Calgary, AB, Canada
Agenda
The seminar fee includes lunch, refreshments and handouts. Non-members joining IEEE within 30 days of the seminar will be rebated 50% of the IEEE registration charge.
Four hours of instruction will be provided. If desired, IEEE Continuing Education Units (0.4 CEUs) will be offered for this course - a small fee of $45 will be required for processing.
Please pay attention to the “Registration Fee” and choose the appropriate choice either with or without CEUs.
All Invited - Please Post