“Partial Discharge and How to Detect it”

#microgrids #battery #IEEE #STEM #energy #generation #engineering #power #distribution #storage #batteries #monitoring #cbm #asset #management #transformers #switchgear #cables #breakers
Share

The IEEE Alabama Section eagerly anticipates an illuminating presentation by Dr. Ammar Kahn, Rugged Monitoring, which delves into the nuanced realm of online asset monitoring software and advance monitoring for AIS/GIS equipment, renewables and that includes transformers, 
switchgears, HV cables and breakers. 

Partial Discharge Monitoring in HV/MV Electrical Assets

Ammar Khan

Rugged Monitoring, Frank Carrel, Quebec City, Quebec, G1N 4N7, Canada

The oil and gas industry (O&G) have traditionally relied on offline and periodic partial discharge monitoring to measure the insulation strength of High and Medium voltage (HV/MV) assets. This method does not consider the transients and electro-mechanical stresses the asset experience in real time load. The online Partial Discharge (PD) monitoring addresses this by providing continuous real time data. Online PD measurement is not new; however, the challenge is to effectively and reliably detect PD in high noise environment and then utilize this data to calculate the Health and Risk index (HI/RI) of the asset. The online PD data can also be used to localize the fault which can be further validated with offline test data. We will also look at methods to harness the online and offline data in one platform and how to leverage the date with analytics based on IEEE algorithms.


Please email RoyBrown@southernco.com after attending the event if you want a PDH certificate.

Contact Roy lee brown if you cannot log in: 205-842-6761 or email for help. 

I will email you a Link that works for me.

We look forward to you joining us and sharing this exciting program.



  Date and Time

  Location

  Hosts

  Registration



  • Date: 07 Oct 2024
  • Time: 04:00 PM to 05:00 PM
  • All times are (UTC-05:00) Central Time (US & Canada)
  • Add_To_Calendar_icon Add Event to Calendar
If you are not a robot, please complete the ReCAPTCHA to display virtual attendance info.
  • Contact Event Hosts
  • Email address to contact for additional info: 

    Austin Norton

    Pinnacle Power Sales

    404-583-1071

    anorton@pinnaclepowersales.com

  • Co-sponsored by Austin Power Pinnacle Power Sales
  • Starts 30 August 2024 09:00 AM
  • Ends 07 October 2024 08:00 PM
  • All times are (UTC-05:00) Central Time (US & Canada)
  • No Admission Charge


  Speakers

Ammar Kahn of Rugged Monitoring

Topic:

“Partial Discharge and How to Detect it”

Biography:

Ammar Khan is the Director of Technology for Rugged Monitoring. He has been working in the 
online asset monitoring industry for 15yrs providing asset performance management software
and advance monitoring for AIS/GIS equipment, renewables and  that includes transformers, 
switchgears, HV cables and breakers. Ammar has  worked closely on several other projects
providing asset monitoring solutions for high voltage equipment. He has over 15 IEEE
publications on partial discharge and previously worked with SAUDI ARAMCO, Saudi Electric
Company, Qualitrol and has experience with other vendor equipment like Camlin, GE and Doble.
He has a master’s in electrical engineering from King Saud University. 