Applying Steady-State Cable Temperature calculations for safe cable operation

#ETAP;Cable #Temperature #Calculation;Safety
Share

IEEE PES/IAS Chapter of Orange County Meeting Notification


Monthly Meeting of the Orange County Chapter of The Power & Energy Society (PES) and the Industry Application Society (IAS)

The presentation is free and dinner can be purchased upon arrival, with choices: Chicken, fish, or vegetarian.

If purchasing meal: $30 for All attendees

Note: sub-charge of 2.75% for all major credit cards

Please specify dinner entree: Chicken, Fish, or Vegetarian

Agenda: 6:00 PM Dinner; 7:30 PM Presentation; 8:45 PM Wrap-Up

Meal: $30 (plus 2.75% for major credit cards); FREE for full-time college students with I.D.

PLEASE RESERVE BY CONTACTING HAMID SUKAR AT:

 asukar@carollo.com or 714-593-5160 (cell)

Please specify a dinner entree:  Chicken, Fish, or Vegetarian

Drawing for FREE DINNER at end of meeting (valid at a future meeting, within one year of winning).

  • Chair: Roger Wilson; Independent Electrical Engineer, 949-285-5559, rogerwilson@cox.net
  • Vice Chair:Ian Varley; RBF/Michael Baker International, 949-855-7064, ivarley@trialphaenergy.com
  • Treasurer: Abdulhamid (Hamid) Sukar; Carollo Engineers, 714-593-5100, asukar@carollo.com
  • Secretary: Brian Chee; AECOM, 515-708-3773, Brian.Chee@aecom.com
  • Publicity: Robert Ryan; Rockwell Automation, 714-938-9037, rryan@ra.rockwell.com

 



  Date and Time

  Location

  Hosts

  Registration



  • Date: 20 Apr 2017
  • Time: 06:00 PM to 08:45 PM
  • All times are (GMT-08:00) US/Pacific
  • Add_To_Calendar_icon Add Event to Calendar

  • Contact Event Host
  • ivarley@trialphaenergy.com

    ASukar@carollo.com

  • Starts 15 March 2017 12:00 AM
  • Ends 20 April 2017 04:00 PM
  • All times are (GMT-08:00) US/Pacific
  • No Admission Charge
  • Menu: Chicken, Fish, Vegetarian


  Speakers

Mr. Victor Andrade, BSEE;  Principal Power Engineer with ETAP Mr. Victor Andrade, BSEE; Principal Power Engineer with ETAP

Topic:

Applying Steady-State Cable Temperature calculations for safe cable operation

Establishing the Current-Carrying Capacity (Ampacity) of underground buried cables plays a vital role when figuring out the maximum power which the cable system can transmit. Equally important is calculating an optimal ampacity in order to operate the cables below their maximum temperature limit. If the temperature exceeds the maximum allowable limit, the reliability and life expectancy of the cable will be reduced. Manufacturers typically publish cable ampacity values at very specific conditions that rarely match actual practice. The Steady-State Cable Temperature calculation determines the operating temperature of cable conductors in a raceway system under a specified loading condition. The calculation is based on the NEC accepted Neher-McGrath approach, which employs a thermal circuit model to represent heat flow situations. We will review hand calculations and also the use of power systems analysis software for these calculations. 

Biography:

Mr. Victor Andrade received his Bachelor's degree in Electrical Engineering from California State Polytechnic University in 2007. At ETAP, Victor is the Applications Engineer responsible for supporting the Gulf Region accounts. Victor’s previous duties included the review of power system studies, ranging from Power Flow, Short Circuit, Protection/Coordination, Arc Flash, Harmonics and Transient Stability. Before joining ETAP, Mr. Andrade worked as a technical support engineer for SKM Systems Analysis, Inc., implementing software testing and V&V procedures, and creating CAPTOR protective device library models.

Mr. Victor Andrade, BSEE; Principal Power Engineer with ETAP

Topic:

Applying Steady-State Cable Temperature calculations for safe cable operation

Biography: