11451-5 Annex G Close Loop Leveling with Power Control Process and Results
Synopsis: ETS-Lindgren Team’s efforts in preparing a systems solution and understanding the practical application of ISO 11451-5, Annex G Reverberation Method with Closed-Loop Power Control. The presentation describes the system, process and recorded test results. There will be a live Reverberation System demonstration.
Annex G uses a volumetric measured field to determine Emax. The Annex G’s volumetric includes the eight field probes with their orthogonal axis (X, Y and Z). Emax is the mean of all 24 maximum field components. The Target Power (PTarget) is scaled to the desired field (Edesired) using the formula shown previously. Further, the four standard deviations (X, Y, Z and Vector Composite) are calculated and recorded. If the standard deviation results are not compliant to the standard then the standard deviation non-compliance must be stated within the report.
Date and Time
Location
Hosts
Registration
- Date: 27 Feb 2025
- Time: 11:30 PM UTC to 02:30 AM UTC
-
Add Event to Calendar
- 965 Explorer Blvd NW
- Huntsville, Alabama
- United States 35806
- Building: East Tower
- Contact Event Hosts
-
- Co-sponsored by Meal Sponsor: ETS-Lindgren
Speakers
Mr. Jack McFadden
11451-5 Annex G Close Loop Leveling with Power Control Process and Results
ETS-Lindgren Team’s efforts in preparing a systems solution and understanding the practical application of ISO 11451-5, Annex G Reverberation Method with Closed-Loop Power Control. The presentation describes the system, process and recorded test results. There will be a live Reverberation System demonstration.
Annex G uses a volumetric measured field to determine Emax. The Annex G’s volumetric includes the eight field probes with their orthogonal axis (X, Y and Z). Emax is the mean of all 24 maximum field components. The Target Power (PTarget) is scaled to the desired field (Edesired) using the formula shown previously. Further, the four standard deviations (X, Y, Z and Vector Composite) are calculated and recorded. If the standard deviation results are not compliant to the standard then the standard deviation non-compliance must be stated within the report.
Biography:
Agenda
Meal – Jason’s Deli
Jason’s Deli sandwiches, Cookies,Sweet/Un-Sweet Tea, and Water
Huntsville Chapter IEEE EMC Society Meeting Thursday, February 27, 2025 5:30 PM | (UTC-06:00) Central Time (US & Canada) | 3 hrs
Join WebEx meeting
https://ieeemeetings.webex.com/ieeemeetings/j.php?MTID=m79b5f73a0e2c0606ea951f2bcea52423
Meeting number: 2538 410 8105 Meeting password: cuGXiBJj273
Join from a video system or application Dial 25384108105@ieeemeetings.webex.com You can also dial 173.243.2.68 and enter your meeting number. To dial from an IEEE Video Conference System: *1 2538 410 8105
Tap to join from a mobile device (attendees only) +1-415-655-0002,,25384108105## United States Toll 1-855-282-6330,,25384108105## United States Toll Free