Kunnekter Fizzix - Increasing Transmission Line Capacity with High-Temperature Connectors

#connector #connectors #transmission
Share

Carl Tamm, founder and President of Classic Connectors, Inc.,  www.classicconnectors.com [classicconnectors.com] and the ClampStar product line will offer a presentation on "high temperature" applications of transmission line connectors, which details the reason that most compression connectors would not pass testing at 250C.  This presentation lays out the reasons, and a solution is offered, allowing utilities to rate exisiting ACSS lines at 250C using their shunts, or reconductor, or build new lines using these connectors for use on ACSS, for which there is really no solution today other than this.

All Southern Company utilities have been using ClampStar for over 15 years, both on large projects and also smaller maintenance applications. Georgia Power's first major project covered all the splices on the Loopers Farm - Rome 230kV, which was Condor SD conductor, in December of 2010.  The ClampStar units in the air today number in the hundreds of thousands.  They have never had a failure.

Carl will detail the hard science and engineering validation behind the limits of legacy connectors, specifically related to high temperatures operations, i.e., temperatures exceeding 93°C, which exemplify the reasons that legacy connectors are not capable of performing on conductors which exceed temperatures much beyond 125°C. A solution will be presented, accompanied by test data substantiating performance testing at 335°C and 390°C conductor temperatures.

 



  Date and Time

  Location

  Hosts

  Registration



  • Add_To_Calendar_icon Add Event to Calendar

Loading virtual attendance info...

  • 3435 Colonnade Parkway
  • Birmingham, Alabama
  • United States 35243
  • Building: South Building
  • Room Number: Auditorium 1S
  • Click here for Map

  • Contact Event Hosts
  • Starts 26 February 2026 02:00 PM UTC
  • Ends 18 March 2026 11:00 PM UTC
  • No Admission Charge


  Speakers

Carl Tamm of Classic Connectors, Inc.

Topic:

Kunnekter Fizzix - Increasing Transmission Line Capacity with High-Temperature Connectors

Biography:

Carl Tamm, President of Classic Connectors, Inc., is a 40-year electrical industry veteran and a leading technical authority on power grid connectors. Deeply involved in shaping industry standards, he serves as a voting member of the Cigre’ US National Committee, the IEEE-PES TP&C Committees, and the NSI C119 committees, including serving as the founding Chair of ANSI C119.7.

Carl’s extensive forensic analysis of hundreds of failed connectors makes him a premier subject matter expert on overhead power line failures. His engineering background provides the scientific foundation for understanding the thermal limitations of legacy hardware.

 

Email:

Address:382 Park Avenue East, , Mansfield, Ohio, United States, 44905





Agenda

Attending in person:

Southern Company Services

3435 Colonnade Pkwy, Birmingham, AL 35243

Drive to the guard shack  with gate.

Tell the guard you are attending the IEEE PES meeting in the auditorium.

Park in the lower North parking deck.

Enter the Atrium to sign in.

Then get escorted back to the auditorium 1S.